![Vulcan-Hart VCCG Series Service Manual Download Page 4](http://html.mh-extra.com/html/vulcan-hart/vccg-series/vccg-series_service-manual_1056751004.webp)
•
VOM with minimum of NFPA-70E CAT III 600V,
UL/CSA/TUV listed. Sensitivity of at least 20,000
ohms per volt. Meter leads must also be rated at
CAT III 600V.
•
Temperature tester (K type thermocouple
preferred) with surface probe.
•
U-Tube or Digital Manometer.
•
Thread sealant suitable for use with natural or
propane gas.
Special
•
Torque wrench capable of measuring at least 25
in-lbs. for tightening thermocouple probe to
griddle plate. Bolt size 5/16"-18.
•
Safekote 60™ or equivalent Heat Transfer and
Anti-Seize Compound rated for 600°F (purchase
locally). Apply to thermocouple probe.
VCCG Series Heavy Duty Gas Griddle - GENERAL
F45533 (1014)
Page 4 of 26