Fig. 6
Water Level Gauge Assembly.
The gauge permits
visual confirmation that water level is being
maintained in the boiler during operation.
•
The correct water level is one-half the height of
the glass.
•
The manual valves at the top and bottom of this
assembly must be fully open. Only close a valve
if the glass tube is damaged.
NOTE:
The appearance of extreme murkiness in the
water indicates inadequate water quality and will
cause failure of controls and the steamer. Warranty
does not cover malfunction due to poor water
conditions. Blowdown and/or clean out the boiler as
outlined in Boiler Blowdown and Steamer Shut Off.
•
The water should be clean and clear.
Water Level Control and Level Sensing Probes.
The probes monitor the water level in the boiler.
•
They determine if sufficent water is present or
more water is required.
VSX BOILER BASE SERIES CONVECTION STEAMERS - COMPONENT FUNCTION AND LOCATION
Page 11 of 82
F24627 (0916)