6.
Reverse procedure to install new burner, nozzle
and orifice.
COMBINATION VALVE
REGULATOR ADJUSTMENT
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
NOTE:
Accurate gas pressure adjustments can only
be made with gas on and burner lit. If incoming line
pressure to valve is less than the minimum stated,
then pressure cannot be set correctly.
Combination valve is preadjusted for natural or
propane gas as specified on the rating plate. Natural
gas rating is 4" W.C., and propane rating is 10" W.C.
1.
Turn gas control valve knob to OFF.
Fig. 37
2.
Remove plug from submanifold and install
Manometer at this point.
Fig. 38
3.
Turn on gas and LIGHT PILOT.
4.
Turn gas control valve knob to ON.
5.
Set thermostat so burners will come on.
6.
Check pressure reading. Manifold Manometer
should match pressure rating on data plate.
Perform adjustment as necessary.
Adjustment
A.
Remove adjustment screw cap.
B.
Turn adjustment screw (1, Fig. 39):
LG Series Fryer - SERVICE PROCEDURES AND ADJUSTMENTS
F45691 (1117)
Page 16 of 23