background image

— 4

 —

Ins

tal

lat

ion

, fo

nct

ion

nem

ent

 et

 en

tre

tie

n

CU

ISI

NIÈ

RES

  A

U  G

AZ 

 À

  S

ECT

IO

NS 

À  S

ERV

ICE

  IN

TEN

SE

DO

CU

MEN

T À

 C

ON

SER

VER

 EN

 C

AS 

DE 

BES

OIN

.

GÉN

ÉRA

LIT

ÉS

Les

 cu

isi

niè

res

 au

 ga

z à

 se

rvi

ce 

int

ens

e à

 se

ctio

ns 

son

t fa

briq

uée

s a

vec

 le

 pl

us 

gra

nd 

soi

n e

t à 

par

tir 

des

mei

lle

urs

 m

até

ria

ux.

 Le

ur 

ins

tal

lat

ion

, u

tili

sat

ion

 et

 en

tre

tie

n a

ppr

opr

iés

 pe

rm

ettr

ont

 d’

en 

obt

eni

r u

n r

end

em

ent

opt

im

al p

end

ant

 de

 no

mbr

eus

es 

ann

ées

.

Il e

st r

eco

mm

and

é d

e li

re 

ce 

man

uel

 au

 co

mpl

et e

t d

e s

uiv

re 

atte

ntiv

em

ent

 to

ute

s le

s in

str

uct

ion

s.

IN

STA

LLA

TIO

N

DÉB

ALL

AG

E

Cet

te 

cui

sin

ièr

e a

 ét

é in

spe

cté

e a

van

t d

e q

uitt

er 

l’u

sin

e. E

n a

cce

pta

nt d

e li

vre

r c

ette

 m

arc

han

dis

e, le 

tra

nsp

ort

eur

en 

ass

um

e l’

ent

ièr

e r

esp

ons

abi

lité

 ju

squ

’à 

la 

liv

rai

son

. Im

méd

iat

em

ent

 ap

rès

 av

oir 

déb

allé

 l’a

ppa

rei

l, v

érif

ier

 s’

il n

’a 

pas

 ét

é e

ndo

mm

agé

 lo

rs 

du 

tra

nsp

ort.

 En

 ca

s d

e d

om

mag

es,

 co

nse

rve

r le

 m

até

rie

l d

’em

bal

lag

e e

t a

vis

er 

le 

 tr

ans

por

teu

r

dan

s le

s 1

5 jo

urs

 su

iva

nt l

a d

ate

 de

 ré

cep

tio

n.

Sor

tir 

l’a

ppa

rei

l d

e s

a c

ais

se 

ave

c s

oin

 et

 le

 pl

ace

r le

 pl

us 

prè

s p

oss

ibl

e d

e l’

em

pla

cem

ent

 pr

évu

, se

ul o

u e

n s

érie

.

Enl

eve

r to

ute

s le

s p

ièc

es 

em

bal

lée

s d

ans

 un

e b

oîte

 de

 ca

rto

n q

ui s

e tr

ouv

e d

ans

 l’e

nce

int

e d

e cu

iss

on,

 le

 m

eub

le 

ou

sur

 le

 de

ssu

s d

es 

cui

sin

ièr

es 

mod

ula

ire

s.

Enl

eve

r le

 câ

ble

 ou

 éc

rou

 à 

l’a

rriè

re 

de 

cha

que

 br

ûle

ur 

ava

nt d

’in

sta

lle

r la

 cu

isi

niè

re.

Ava

nt l

’in

sta

lla

tio

n, s

’as

sur

er 

que

 l’a

lim

ent

atio

n é

lec

triq

ue 

(m

odè

les

 po

urv

us 

d’u

n fo

ur 

à a

ir 

pul

sé 

seu

lem

ent

) e

t le

 

typ

e d

e g

az 

(na

tur

el o

u p

rop

ane

) d

e l’

im

meu

ble

 co

rre

spo

nde

nt a

ux 

spé

cifi

cat

ion

s de

 la

 pl

aqu

e s

ign

alé

tiq

ue 

se 

tro

uva

nt à

 l’i

nté

rie

ur 

de 

la 

boî

te 

du 

brû

leu

r d

u p

ann

eau

 in

fér

ieu

r. L

a pl

aqu

e s

ign

alé

tiq

ue 

ind

iqu

e l’

alim

ent

atio

n, l

a

pha

se,

 le

 cy

cle

, le

 co

ura

nt à

 pl

ein

e c

har

ge,

 le

 no

mbr

e de

 B

TU

 ai

nsi

 qu

e le

 ty

pe 

de 

gaz

. S

’ils

 ne

 co

rre

spo

nde

nt p

az,

ne 

pas

 in

sta

lle

r l’

app

are

il e

t co

mm

uni

que

r s

ans

 ta

rde

r a

vec

 vo

tre

 dé

tai

lla

nt.

D

É

GAGEMENTS REQUIS POUR INSTALLA

TION

Brûleurs découverts: 152 mm ( 6 po) requis à l’arrière de toute construction combustible et aucun dégagement requis de

toute construction incombustible. 254 mm (10 po) requis sur les côtés de toute construction combustible et aucun 

dégagement requis de toute construction incombustible.

Plaques à bouillir / Plaques à frire manuelles: 152 mm (6 po) requis à l’arrière de toute construction combustible et aucun

dégagement requis de toute construction incombustible. 102 mm (4 po) requis sur les côtés de toute construction 

combustible et aucun dégagement requis de toute construction incombustible.

Plaques à frire / Plaques circulaires à thermo-régulateur: 152 mm (6 po) requis à l’arrière de toute construction 

combustible et aucun dégagement requis de toute construction incombustible. 51 mm (2 po) requis sur les côtés de 

toute construction combustible et aucun dégagement requis de toute construction incombustible.

Table de travail:

  Aucun dégagement requis sur les côtés et à l’arrière de toute construction combustible et incombustible

Fours:  Four conventionnel – 76 mm (3 po) requis sur les côtés et à l’arrière de toute construction combustible et aucun

dégagement requis de toute construction incombustible. Four à air pulsé – 25 mm (1 po) requis sur les côtés et à l’arrière

 de toute construction combustible et aucun dégagement requis de toute construction incombustible.

Summary of Contents for HDR V series

Page 1: ...ol for this product you may still be qualified to perform the procedures described in this manual This manual is not intended to be all encompassing If you have not attended a service school for this...

Page 2: ...ANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY Do not store or use gasoline or other flamma...

Page 3: ...S CONFIGURATION OF HEAVY DUTY RANGES 12 18 24 WIDE EXPANDO RANGES 36 WIDE DOUBLE FRENCH TOP V1FT36 VGM36 VGMT36 V236H V2BG18 V2BG8T V4B36 V4B36U V6B36 V6B36U VWT36 V2FT36 36 WIDE CHARBROILER 24 WIDE C...

Page 4: ...rical service Convection Oven Models only and type of gas supply natural or propane to make sure they agree with the specifications on the rating plate located on the inside of the burner box lower pa...

Page 5: ...Make sure there is an adequate supply of air in the room to allow for combustion of the gas at the burners INSTALLATION CODES AND STANDARDS Your range s must be installed in accordance with In the Un...

Page 6: ...s installation position Separate instructions for installing casters to the range are included with the casters Note Iftherangeisinstalledoncastersandismovedforanyreason itisrecommendedthattherange be...

Page 7: ...nsult your gas company 2 Align the front edge of the ranges and adjust the legs to bring the manifolds together inline for connection Clamps may be used to pull the ranges together 3 Connect the union...

Page 8: ...d before lighting unit B Check all joints beyond gas valve solenoid after unit is lit After piping has been checked for leaks all piping receiving gas should be fully purged to remove air TESTING THE...

Page 9: ...h a flexible electric supply cord are provided with a three prong grounding plug It is imperative that this plug be connected properly into a properly grounded three prong receptical If the receptical...

Page 10: ...th of time to purge air will vary 3 Turn top burner valve knobs to OFF 4 Wait 30 seconds 5 Using a taper light the pilot s 6 If pilot fails to light wait 5 minutes and repeat Steps 1 through 5 Nightly...

Page 11: ...use the griddle The griddle requires no breaking in or seasoning OPERATING SUGGESTIONS Standard Oven If you have a standard oven use your normal recipe times and temperatures Convection Oven The conve...

Page 12: ...LATE SURFACE CLEAN To produce evenly cooked browned products keep griddle free of carbonized grease Carbonized grease on the surface hinders the transfer of heat from the griddle surface to food This...

Page 13: ...and bright General Cleaning Useordinarysoapordetergentandwaterforroutinecleaningofstainlesssteel Topreventwaterspots and streaks rinse thoroughly with warm water and wipe dry with a soft clean cloth T...

Page 14: ...ent never use ordinary steel scrapers Particles of ordinary steel may become embedded in or lodge on the surface of the stainless steel These will rust causing unsightly stains and possible contaminat...

Page 15: ...ce and parts information concerning this model contact the Authorized Service Agency in your area refer to the manufacturer s website for a complete listing of Authorized Service and Parts depots or c...

Page 16: ...Oven burner bottom or baffles improperly installed s n a p d e p r a W n a P f o e g d E o t g n i l l u P Oven not level Uneven Bake Front to Rear Overactive flue Call Service Range not level front t...

Page 17: ...or fit Call Service Sticking Top Burner Valves Oven door left open e c i v r e S l l a C t u p n i s a g t n e i c i f f u s n I n o i t i n g I r o o P Poor air to gas adjustment Call Service Restric...

Page 18: ......

Page 19: ......

Page 20: ...Injecteur de la veilleuse obstru Communiquer avec le service de l entretien Lumi re d allumage principale du br leur obstru e Communiquer avec le service de l entretien Robinet de commande obstru Com...

Page 21: ...bien Temp rature trop basse Cuisson trop longue Thermostat mal talonn Communiquer avec le service de l entretien Alimentation en gaz insuffisante Communiquer avec le service de l entretien Flamme de l...

Page 22: ...n permanence et ne requi rent aucun autre entretien CONDUIT D VACUATION Une fois par ann e s assurer que le conduit d vacuation n est pas obstru SERVICE DE L ENTRETIEN ET PI CES DE RECHANGE Pour l ent...

Page 23: ...noxydable Des particules ou de l acier ordinaire risquent de s incruster ou de se loger dans la surface en acier inoxydable provoquant une l g re formation de rouille et possiblement la contamination...

Page 24: ...incelant Nettoyage g n ral Utiliser du savon ordinaire ou du d tergent et de l eau pour le nettoyage quotidien de l acier inoxydable Pour viter la pr sence de taches d eau et de rayures rincer l appar...

Page 25: ...laque frire Vider la graisse tous les jours Nettoyer la plaque frire r guli rement MAINTENIR LA SURFACE DE LA PLAQUE FRIRE PROPRE Pour obtenir une cuisson uniforme et des produits parfaitement dor s n...

Page 26: ...tion ou appr tage SUGGESTIONS D UTILISATION Four conventionnel Si vous poss dez un four conventionnel vous pouvez utiliser vos recettes normales de cuisson et de temp ratures Four air puls Le four air...

Page 27: ...allumer reprendre les tapes 1 6 Arr t nocturne Mettre le thermostat OFF arr t la veilleuse demeure allum e Arr t complet Mettre le thermostat et le robinet d arr t OFF arr t Mettre le robinet de gaz p...

Page 28: ...munis d un cordon d alimentation flexible sont pourvus d une fiche de mise la terre trois broches La prise dans laquelle elle est branch e doit tre correctement mise la terre Si elle ne l est pas com...

Page 29: ...de proc der l allumage de l appareil B V rifier tous les joints partir de la soupape gaz apr s l allumage Apr s avoir enray toute possibilit de fuite purger la conduite de gaz pour vacuer tout l air...

Page 30: ...des cuisini res et r gler les pattes de fa on ce que les tubulures d alimentation soient en ligne pour le raccordement Utiliser des brides pour joindre les cuisini res ensemble 3 Raccorder les raccor...

Page 31: ...et doit tre d plac e pour une raison ou une autre il est conseill de la niveler nouveau d avant en arri re et d un c t l autre NIVELAGE Installation sur un muret Les cuisini res doivent d passer le de...

Page 32: ...ment d air de la chambre de combustion S assurer d une bonne ventilation dans le local pour permettre la combustion des gaz CODES D INSTALLATION ET NORMES L installation de votre cuisini re doit se fa...

Page 33: ...e se trouvant l int rieur de la bo te du br leur du panneau inf rieur La plaque signal tique indique l alimentation la phase le cycle le courant pleine charge le nombre de BTU ainsi que le type de gaz...

Page 34: ...05 MM 12 PO DE 914 MM 36 PO DOUBLE DE 914 MM 36 PO FOUR CONVENTIONNEL FOUR AIR PULS BASE DE RANGEMENT 914 MM 36 PO C OUVERTE PLEINE GRANDEUR BASE MODULAIRE PLEINE GRANDEUR 914 MM 36 PO DE 914 MM 36 PO...

Page 35: ...NT NE PAS FAIRE FONCTIONNER CET APPAREIL L installation le r glage la modification et l entretien incorrects de cet appareil peuvent causer des dommages mat riels des blessures et m me la mort Lire le...

Page 36: ...vez assist un atelier de formation sur ce produit vous pouvez aussi tre qualifi pour ex cuter les proc dures d crites dans ce manuel Ce manuel peut ne pas couvrir tous les aspects de cet appareil Si v...

Reviews: