Program Item
Key Sequence
LED Status
ON
OFF
Left
Right
•
Press and hold 6 to light all display
elements.
all
*.*.*.*.*.*.*·*·*
*.*.*.*.*.*.*·*·*
•
Press 7 to test ignition status input. Turn
valve on/off, and press 7 again to update
display.
5, 7
Gas valve on.
5, 7
PILOT ON
PILOT ON
Gas valve off or ignition module lock out.
5
7
PILOT OF
PILOT OF
Temperature
Ready Level
•
Press 6 to view the cooking cycle lock out
temperature (always °F). To edit, enter the
desired lock out temperature (rand 0 to
99°F).
all
READY
40
F
More Service
Programming
Level
•
Press 8 to enter the More Service
Programming. To edit one of the
selections, enter the number desired. To
exit a selection, press V to accept and
return to More Service Programming.
4, 5, 6,
7, 8
MORE
SERVICE
•
Press 4 to view or edit the Shake Alarm
duration: 0-98 seconds; 99-continuous
alarm until canceled manually.
DT-DUR
05
DURATION
•
Press 5 to view or edit the Hold Alarm
duration: 0-98 seconds; 99-continuous
alarm until canceled manually.
HD-DUR.
·05
DURATION
•
Press 6 to view of edit the Cooking cycle
cancel delay; 0-10 seconds.
CANCEL.
·01
DELAY
•
Press 7 to view or edit the number of
basket lifts.
all
LIFTS
0
, 1, or 2
Press Toggle key to select the number of
basket lifts.
0 = none; 1 = one lift; 2 = two lifts.
•
Press 8 to view or edit the fryer's Energy
Source, electric or gas heat.
all
FRYER
ELECTRIC
or
gAS
Press Toggle key to select the fryer's
Energy Source, electric or gas heat.
GR Series Gas Fryers with NCC Controls (formerly Tridelta / Built after 3/05) - SERVICE PROCEDURES AND
ADJUSTMENTS
F35660
Rev. A (0717)
Page 30 of
56