6.
Remove nuts and clamps (Fig. 15) from element
assembly.
Fig. 15
NOTE:
When installing high limit switch probe, route
capillary tube and center bulb between clamps before
tightening.
7.
Reverse procedure to install.
LIFT ASSIST SPRINGS
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Heating elements may be hot. Use
care when handling them.
NOTE:
If one spring breaks, replace both springs.
NOTE:
Heating elements are to remain upright
through entire procedure.
1.
Raise heating elements (1, Fig. 16) and place
2x4 lumber (2) under them for support.
2.
3.
Remove screws and electrical panel (3, Fig. 16).
Fig. 16
4.
Loosen all eye bolt mounting nuts (1, Fig. 17) to
release tension on springs.
5.
Remove lift assist spring (4, Fig. 17) from eye bolt
hooks (2).
6.
Remove lift assist spring from hanger (3, Fig.
17).
Fig. 17
NOTE:
Leave electrical panel and electrical cover off.
7.
Reverse procedure to install.
8.
Perform LIFT SPRING ADJUSTMENT.
9.
Install electrical panel and ELECTRICAL
COVER .
CEF40/75 FRYER - REMOVAL AND REPLACEMENT OF PARTS