Leave 1/8" exposed wire showing at
contactor power terminal connections (Fig. 23) to
prevent capture of wire insulation. Capture of
insulation at power connections can lead to
overheating and premature failure.
Fig. 23
4.
Reverse procedure to install.
TRANSFORMER
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
NOTE:
Document wire connections.
2.
Disconnect wires from transformer (Fig. 24).
Fig. 24
3.
Remove screws and trasformer.
4.
Reverse procedure to install.
FUSE / FUSE HOLDER
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
Replace fuse:
A.
Remove fuse access cover.
B.
Remove fuse cap and fuse.
Fig. 25
C.
Reverse procedure to install.
2.
Replace fuse holder:
A.
Remove ELECTRICAL COVER .
NOTE:
Document wire connections.
B.
Disconnect wires from fuse holder.
C.
Remove screws, nuts, and fuse holder.
D.
Reverse procedure to install.
CIRCUIT BREAKER
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
NOTE:
Only CEF75 fryers have circuit breakers.
1.
NOTE:
Document wire connections.
2.
Disconnect wires from circuit breaker (Fig. 26).
CEF40/75 FRYER - REMOVAL AND REPLACEMENT OF PARTS
F45657 (0517)