CARE & MAINTENANCE

 WARNING

FOR YOUR SAFETY

• 

Do NOT touch or move fire pit for 

at least 45 minutes after use.

• 

Burner is hot to the touch.

• 

Allow burner to cool before 
touching.

To enjoy years of outstanding performance from your fire pit, make sure you 

perform the following maintenance activities on a regular basis:

1. Use warm soapy water for cleaning. Never use flammable or corrosive 

 

cleaning agents.

2. While cleaning your unit, be sure to keep the area around the burner and 

control compartment dry at all times. Do not submerge the control valve 
assembly. If the gas control is submerged in water, do NOT use it. It must  

be replaced. Make sure fire pit has cooled completely before cleaning or 

covering with a cover. 
A. Keep the appliance area clear and free from combustible materials, 

gasoline and other flammable vapors and liquids. 

 

B. Do not obstruct the flow of combustion and ventilation air.

 

C. Keep the ventilation opening(s) of the cylinder enclosure free and clear 
from debris.

3. Air flow must be unobstructed. Keep controls, burner, and circulating 

 

air passageways clean. Signs of possible blockage include:

• Gas odor with extreme yellow tipping of flame.
• Fire pit does NOT reach the desired temperature.
• Fire pit glow is excessively uneven.
• Fire pit makes popping noise.
• Spiders and insects can nest in burner or orifices. This dangerous 

condition can damage fire pit and render it unsafe for use. Clean 

burner holes by using a heavy-duty pipe cleaner. Compressed air  
may help clear away smaller particles.

• Carbon deposits may create a fire hazard. Clean burner screen with 

warm soapy water if any carbon deposits develop.

Note: 

In a salt-air environment (such as near an ocean), corrosion 

occurs more quickly than normal. Frequently check for corroded areas 
and repair them promptly.

SERVICE:

Only a qualified service person should 

 

repair gas passages and associated  
components.

Caution: 

Always allow fire pit to cool 

 

before attempting service.

STORAGE

:

Between uses:

• Turn control knob OFF.
• Disconnect LP source.
• Store fire pit in an area sheltered 

from direct contact with 
inclement weather (such  
as rain, sleet, hail, snow, dust 
and debris).

• If desired, cover fire pit to 

protect exterior surfaces and 
to help prevent build-up in air 
passages. 

During periods of extended 
inactivity or when transporting:

• Turn control knob OFF.
• Disconnect LP source and move 

to a secure, well-ventilated 
location outdoors.

• Store fire pit in an area sheltered 

from direct contact with 
inclement weather (such as 
rain, sleet, hail, snow dust and 
debris).

• If desired, cover fire pit to 

protect exterior surfaces and 
to help prevent build-up in 
air passages. Never leave LP 
cylinder exposed to direct 
sunlight or excessive heat.

Note: 

Wait until fire pit is 

 

cool before covering.

Summary of Contents for 62411

Page 1: ...CH YOUR RECEIPT HERE Keep a copy of your proof of purchase or order confirmation which will be needed if you need to contact us about warranty coverage Purchase Date 1 US R C R R FOR YOUR SAFETY If yo...

Page 2: ...anual before attempting to assemble operate or install this appliance If you have any questions regarding the product please call us toll free at 866 985 7877 email us at cservice welltraveled net or...

Page 3: ...anel 1 1 Side Panel 2 1 Side Panel 3 Door Frame 1 Side Panel 4 1 Connecting Rod 1 Gas Tank Bracket Side 1 Gas Tank Support Bottom 1 Fire Glass 2 Bags Protective Cover 1 Bolt 6x22mm Washer Qty 4 Bolt 8...

Page 4: ...sides Keep gasoline and other flammable liquids and vapors well away from fire pit Store the propane cylinder outdoors in a well ventilated space out of the reach of children Never store the propane c...

Page 5: ...cservice welltraveled net Place all parts on a soft level surface for assembly Tools Required for Assembly not included Leak Detection Solution Estimated Assembly Time 60 Minutes DO NOT over tighten...

Page 6: ...sembled panels Attach the Table Top to the assembled panels with 4 Washer Spring Washer Nuts N NOTE Tighten all the Bolts and Nuts Hardware Used 4 Bolt 8x40mm Nut M8 Washer Spring Washer 4Attach the C...

Page 7: ...ust not be stored in a building garage or any other enclosed area The maximum inlet gas supply pressure 250 psi the minimum inlet gas supply pressure 5 psi The minimum hourly of 10 000 BTU is required...

Page 8: ...connect an unregulated propane cylinder to the fire pit Attach regulator to cylinder Complete attachment Install cylinder Do not store a spare LP gas cylinder under or near this appliance Never fill...

Page 9: ...eak test If bubbles continue appearing the hose should be returned to the place of purchase 3 If leak is at regulatory cylinder valve connection disconnect reconnect and perform another leak test If y...

Page 10: ...cooled down after use before placing Lid on Table Top or touching any surfaces Failure to comply with these instructions may result in serious bodily injury DANGER FOR OUTDOOR USE ONLY CARBON MONOXID...

Page 11: ...signs of spider or insect nests in fire pit orifices m All burner passages are clear m All air circulation passages are clear m Clothing or other protective material should not be hung from the fire p...

Page 12: ...ven Fire pit makes popping noise Spiders and insects can nest in burner or orifices This dangerous condition can damage fire pit and render it unsafe for use Clean burner holes by using a heavy duty p...

Page 13: ...ockage Control knob is not in ON position Turn control knob to ON Burner flame is low Gas pressure is low Turn cylinder valve OFF and replace cylinder Outdoor temperature is less than 40 F and tank is...