1 Introduction 

The SCP1000 pressure demonstrator is designed to give a quick access and understanding on the 
performance and capabilities of the SCP1000 pressure component. This document describes how 
to install the required software and how to use the SCP1000 DEMO KIT and Graphical User 
Interface (GUI) software version 2.5.  
 
SCP1000 DEMO KIT package includes: 

 

SCP1000-D01 sensor soldered on chip carrier PCB (see Figure 1 on next page) 

 

USB interface card inside the demo box (see Figure 1 on next page) 

 USB 

cable 

 

CD-ROM with documentation, drivers and GUI software running on PC 

 
The SCP1000 DEMO KIT supports SCP1000-D01 and SCP1000-D11 sensors. 
 
The graphical user interface is designed and tested to run in most commercial computers. System 
requirements: 

 

Operating system: Windows XP or Windows 2000 with SP1 or higher 

 

Communication interface: USB 2.0 or 1.0 

 

The SCP1000 demo is powered from the USB port. For minimizing the noise introduced by the 
host PC in pressure measurements, a laptop operating on battery is recommended (mains supply 
disconnected). 
 

Quick start for using the SCP1000 DEMO KIT 

Please follow the steps below: 

1. Insert 

CD-ROM 

2.  Setup the hardware 

Connect the USB cable to the demo and to PC's USB port 

3.  Install the USB driver, after the PC has found the device 

When the PC detects the new USB device, do not let Windows to detect the driver, 
address the USB driver from folder:  

CD-ROM\SCP1000 demo - Virtual Com Port Drivers\ 

NOTICE, if you have already installed the SCA3000 demo to your computer, you 
do not need to install the USB driver for the SCP1000 demo 

4.  Install the GUI software  

Install the GUI software by running the “

setup.exe

" from folder: 

CD-ROM\SCP1000 demo - ver 2.5 – Installer

 

Do not change the installation destination 

5.  Start the GUI software 

- From 

Start 

 Programs 

 SCP1000-USB-DEMO-VER.2.5  

 SCP1000-USB-DEMO-VER.2.5 

 
When using the SCP1000 DEMO KIT with GUI software: 

  The DEMO KIT should be connected to PC before the GUI software is started 

  Exit the GUI software before unplugging the DEMO KIT from PC (button in upper right 

corner of the GUI) 

  After GUI software is stopped, the DEMO KIT can be unplugged from the PC (the SCP1000 

DEMO KIT uses virtual serial COM port driver, so it can not be found as a USB device).  

 
 

Summary of Contents for SCP1000

Page 1: ...ess mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer IC Socket Relay Connector Our parts cover such applications as commercial industrial and automotives areas We are looking forward to setting up business relationship with you and hope to provide you...

Page 2: ...Doc Nr 8268000 03 SCP1000 DEMO KIT User Manual ...

Page 3: ...t up and Reset demo 7 4 1 3 Meas results 8 4 1 4 Register config 8 4 1 5 Pres offset adjustment 9 4 1 6 Setup 10 4 2 Uninstalling the GUI and USB driver 10 5 Using the SCP1000 demo without the GUI software 11 5 1 Establishing the connection 11 5 2 Communication commands 12 6 Using two SCP1000 demo kits simultaneously 14 7 USB interface board circuit diagram 15 8 USB interface board PCB layout 17 9...

Page 4: ...rements a laptop operating on battery is recommended mains supply disconnected 2 Quick start for using the SCP1000 DEMO KIT Please follow the steps below 1 Insert CD ROM 2 Setup the hardware Connect the USB cable to the demo and to PC s USB port 3 Install the USB driver after the PC has found the device When the PC detects the new USB device do not let Windows to detect the driver address the USB ...

Page 5: ...igure 2 below SCP1000 PCB1 with soldered SCP1000 D01 USB interface board USB cable SCP1000 sensor pin 1 ATST TRIG DRDY CLK DVDD DVSS pin 7 DVDDS AVSS pin 14 AVDD CSB MISO MOSI SCK PD pin 8 SCP1000 sensor Demo reset Figure 1 SCP1000 DEMO KIT USB interface board and SCP1000 PCB Virtual serial port driver GUI sw PC USB cable USB interface board SCP1000 PIC µC µC_VDD 3 3V SPI TWI data transfer AVDD 3 ...

Page 6: ...cale pressure and temperature displays press Reset displays to apply the changes 5 Capture pressure data to file browse for file name and location then press start data logging Every data point is saved by default the number of saved data points can be reduced 6 Open close the window extension with arrow button 7 Pressure mbar and altitude m displays 8 Select units mbar C m or inHg F ft 9 Selected...

Page 7: ... the offset adjustment from the SCP1000 EEPROM 1 Activate High resolution measurement mode Meas results display pressure results are corrected by values read from EEPROM 1 2 Back to Meas results display Displays register config pres offset adjustment setup reset demo User changes display from pull down menu NO YES 1 more information on SCP1000 offset adjustment in Figure 9 and in TN48 2 If the pre...

Page 8: ...ort number please disconnect all other USB serial port devices from the PC and restart the GUI software Figure 5 USB serial port selection pop up window 4 1 2 Start up and Reset demo During the GUI software start up or after selecting Reset demo from the Display pull down menu the MCU inside the SCP1000 demo detects automatically the correct sensor type and serial bus SPI TWI Then the MCU reads th...

Page 9: ... following units Figure 7 Meas results display mbar C m or inHg F ft Some of the actions controls listed above can be found from the extension part of the window which can be accessed by pressing the arrow button see Figure 3 and Table 1 The Trig measurement button is displayed in the extension part of the window only when the SCP1000 is in low power measurement mode The Table 5 information is pre...

Page 10: ...display In offset adjustment display user can Figure 9 Pressure offset adjustment display Program the SCP1000 offset adjustment in to the SCP1000 internal EEPROM registers USERADATA1 and USERDATA2 Start offset adjustment button Read the current SCP1000 offset adjustment data from the two EEPROM registers Read current adjustment data button Reset the SCP1000 offset adjustment data by writing zeros ...

Page 11: ...tware see further details from section 5 In this example the SCP1000 DEMO KIT uses COM4 serial port Standard window frames can be enabled disabled In Figure 10 the window frames are disabled Figure 10 Setup display 4 2 Uninstalling the GUI and USB driver The GUI software and the USB driver FTDI Serial Converter Driver can be removed from Windows Control Panel Add Remove Programs Please notice that...

Page 12: ...erminal software can not be open at the same time Follow the steps below to open the HyperTerminal connection 1 Connect SCP1000 DEMO KIT with USB cable to PC 2 Open GUI software to see the correct COM port number SETUP display see Figure 10 3 Close the GUI software 4 Open the pre configured Windows HyperTerminal software from the DEMO KIT CD ROM SCP1000_Demo_pre configured_HyperTerminal_connection...

Page 13: ...ower On and or and MCU detects the SCP1000 product type and serial bus SPI or TWI MCU reads the offset difference from SCP1000 EEPROM MCU does not write the low noise configuration commands Edit registers Register edit commands WD Write Direct register RD Read Direct register WI Write Indirect register RI Read Indirect register WE Write EEPROM register RE Read EEPROM register RS SCP1000 startup se...

Page 14: ...ion via 3 direct registers please see section 3 3 1 in SCP1000 Product Family Specification 8260800 for further details RI Read SCP1000 indirect register MCU performs the indirect read operation via 3 direct registers please see section 3 3 1 in SCP1000 Product Family Specification 8260800 for further details WE Write SCP1000 EEPROM register MCU performs the EEPROM write operation via 3 direct reg...

Page 15: ...ning controlling or air flow measurements differential pressure measurement is required To support these kinds of applications two or even more SCP1000 demo kits can be used simultaneously on one PC In order to use two SCP1000 demo kits simultaneously follow the steps below 1 Install the GUI software and USB driver as instructed above see section 2 2 Connect the 1st SCP1000 demo kit to PC 3 Start ...

Page 16: ...ace board circuit diagram SCP1000 demo USB interface board circuit diagram is presented in following pages Figure 13 SCP1000 DEMO KIT USB interface board circuit diagram sheet USB VTI Technologies Oy 15 19 www vti fi Doc Nr 8268000 03 Rev 0 03 ...

Page 17: ...SCP1000 DEMO KIT User Manual VTI Technologies Oy 16 19 www vti fi Doc Nr 8268000 03 Rev 0 03 Figure 14 SCP1000 DEMO KIT USB interface board circuit diagram sheet MCU ...

Page 18: ...USB interface board PCB layout and silkscreen is presented below Figure 15 SCP1000 demo USB interface board PCB layout left top right bottom Figure 16 SCP1000 demo USB interface board silkscreen left top right bottom VTI Technologies Oy 17 19 www vti fi Doc Nr 8268000 03 Rev 0 03 ...

Page 19: ...he USB port where the demo is connected SCP1000 demo may not work properly if your PC has multiple USB serial ports installed Please remove all other USB serial port devices including the SCA3000 demo Close Windows HyperTerminal software if you have used it Re install the FTDI USB Serial port driver 1 Unplug the demo from PC 2 Uninstall the FTDI USB Serial Converter Drivers from Control Panel Add ...

Page 20: ...VTI Technologies Oy Branch Office Frankfurt Rennbahnstrasse 72 74 D 60528 Frankfurt am Main Germany Tel 49 69 6786 880 Fax 49 69 6786 8829 E mail sales de vti fi USA VTI Technologies Inc One Park Lane Blvd Suite 804 East Tower Dearborn MI 48126 USA Tel 1 313 425 0850 Fax 1 313 425 0860 E mail sales vtitechnologies com Japan VTI Technologies Oy Tokyo Office Tokyo to Minato ku 2 7 16 Bureau Toranomo...

Reviews: