![VTI SCP1000 User Manual Download Page 14](http://html.mh-extra.com/html/vti/scp1000/scp1000_user-manual_1056070014.webp)
SCP1000 DEMO KIT
User Manual
The pressure (
Pres
) and temperature (
Temp
) is sent to PC in [Pa] and in 10
×
[°C] format. Example of
SCP1000 USB demo output data in high resolution mode below:
%102778 256$
→
pressure = 102778 Pa
temperature = 25.6 °C
%102779 257$
→
pressure = 102779 Pa
temperature = 25.7 °C
%102776 256$
→
pressure = 102776 Pa
temperature = 25.6 °C
Commands that are used to control the MCU of the USB demo are listed in Table 3 below.
Table 3. Commands for the USB demo MCU.
MCU
Command
Command description
##
User can reset the MCU software and jump to the sw beginning by giving
this command
*
Start / interrupt command
VD
Display MCU version details
FF
Set MCU software to measurement mode selection mode
Commands that are used to read/write the SCP1000 registers and to control the SCP1000 are
listed in Table 4 below. The register address and data is always in hex format unless otherwise
noted.
Table 4. Commands for the SCP1000.
SCP1000
command
Command description
WD
Write SCP1000 direct register
RD
Read SCP1000 direct register, register width is 08 or 16 (in dec format)
WI
Write SCP1000 indirect register,
MCU performs the indirect write operation via 3 direct registers, please
see section 3.3.1 in “SCP1000 Product Family Specification 8260800” for
further details
RI
Read SCP1000 indirect register,
MCU performs the indirect read operation via 3 direct registers, please
see section 3.3.1 in “SCP1000 Product Family Specification 8260800” for
further details
WE
Write SCP1000 EEPROM register,
MCU performs the EEPROM write operation via 3 direct registers, please
see section 3.4.1 in “SCP1000 Product Family Specification 8260800” for
further details
RE
Read SCP1000 EEPROM register,
MCU performs the EEPROM read operation via 3 direct registers, please
see section 3.4.2 in “SCP1000 Product Family Specification 8260800” for
further details
RS
Reset SCP1000:
- set PD pin high, set PD pin low
- perform the SCP1000 initialization status check, please see section
2.1.2.1 in “SCP1000 Product Family Specification 8260800” for further
details
LN
Low noise configuration:
- write 0x2D to direct register ADDPTR (0x02)
- write 0x03 to direct register DATAWR (0x01)
- write 0x02 to direct register OPERATION (0x03)
Please see section 2.1.3 in “SCP1000 Product Family Specification
8260800” for further details
RP
Reference pressure (for pressure offset adjustment)
Please see "TN48 SCP1000 Pressure Offset Adjustment" for further
details.
VTI Technologies Oy
13/19
www.vti.fi Doc.Nr.
8268000.03
Rev.0.03