background image

 

 

PE/GND    Vent Outlet    AC Output Receptacle(Intelligent Cooling Fan 

是标注

错误

)    LCD Display    Power On/Off     Mode1/Mode2 Shift 

 

PE/GND    AC-L  AC-PE/GND  Vent Outlet    AC Output Receptacle   

Overload Protection    LCD Display    Power On/Off     Mode1/Mode2 Shift

 

P.S

.: 

AC Output Receptacle:

For  application demands of different geographic 

areas all over the world,  there  are many different kinds of optional AC 

Summary of Contents for VST1000

Page 1: ...ase Power Inverter Special Feature with LCD display Battery capacity rate Battery voltage AC voltage AC power Can be used to resistance inductive and capacitive load such as air conditioner fridge pum...

Page 2: ...input 110V 120V 220V 230 240Vac output Pure sine wave output Frequency 50Hz 60Hz CE and RoHS Approved 24 months warranty ODM OEM available Before using the inverter you need to read and save the safet...

Page 3: ...tery voltage AC voltage AC power Complete isolation type inverter technology Continuous operation at full power Wide DC input voltage range Wide working temperature range Low output harmonic distortio...

Page 4: ...er Attentions Do not attempt to connect the any other power source including any AC power source Make sure the opening to the ventilation fan and vent holes are not blocked To avoid electrical hazard...

Page 5: ...ries will damage it Do not attempt to repair the fault inverter yourself otherwise it may lead to a serious accident Please contact the manufacture s engineer 3 Functions This pure sine wave inverter...

Page 6: ...6 Intelligent Cooling Fan DC Input Terminal 3 2 AC Output Panel Vent Outlet AC Output Receptacle LED Display On Off Switch...

Page 7: ...7 Vent Outlet AC Output Receptacle LED Display Power On Off Mode1 Mode2 Shift PE GND Vent Outlet AC Output Receptacle LED Display Power On Off...

Page 8: ...n Off Mode1 Mode2 Shift PE GND AC L AC PE GND Vent Outlet AC Output Receptacle Overload Protection LCD Display Power On Off Mode1 Mode2 Shift P S AC Output Receptacle For application demands of differ...

Page 9: ...ntinuous wattage load of that appliance The startup load of an appliance is a major factor of whether this inverter can power it Startup load is momentary With many appliances it is approximately twic...

Page 10: ...s the same as a single battery Parallel voltage stays the same as a single battery amperage increases Series Parallel both voltage and amperage increase 5 Protection Inverter is equipped with numerous...

Page 11: ...input voltage has been reversed that has blown the fuses Correct the polarity of the input connections and replace the fuse If the unit does not work after replacing the fuse the unit has been permane...

Page 12: ...er temperature I N P U T Bat Voltage Range 11V 15 5V 12V version 22V 31V 24V version 44V 62V 48V version Efficiency More than 90 Protection Battery Low Alarm Battery Low Shutdown Battery Polarity Reve...

Page 13: ...rther improvement of products 8 Maintenance and Warranty The casing of the inverters may be cleaned regularly with a damp cloth not wet to prevent accumulation of dust and dirt The screws on the DC in...

Page 14: ...2 Display AC Voltage 3 Light over AC V lighting 4 Light over Mode1 lighting Status display Battery capacity AC Voltage One Touch Option Button 1 Display Battery Capacity rate 2 Display AC Output Power...

Page 15: ...etween 0 9xVnom and 1 29xVnom where Vnom is 12V 24V 48V depending on model and must be able to supply sufficient current to inverter The following table displays the recommended battery cable Fuse Bat...

Page 16: ...lack 40A 12 480Ah 24V 10mm 2 Red 2 Black 20A 12 240Ah 48V 6mm 2 Red 2 Black 10A 12 120Ah 4000W 12V 25mm 2 Red 2 Black 40A 12 640Ah 24V 16mm 2 Red 2 Black 20A 12 320Ah 48V 10mm 2 Red 2 Black 10A 12 160...