15
Touch again“Option” Button
1)Display Battery Capacity rate
2)Display DC Voltage
3)Light over “DC-V” lighting
4)Light over “Mode1” lighting
Status display:Battery capacity(%),DC Voltage
Mode2----Automatic Turn Page
Mode2:Automatic Turn Page
Long press “Option” Button and hold 5s
1)Long press “Option” Button and hold for 5s until “Mode2” lighting then release
2)Every 3s will display one status
3)Display in turn:AC Voltage,AC Output Power,DC Voltage,Battery Capacity Rate(%)
Appendix II:Recommend
For correct operation, the battery voltage shoul
d be between 0.9xVnom and 1.2
9
xVnom
where
Vnom is 12V,
/
24V
/
48V depend
ing on model, and must be able to supply sufficient current to
inverter. The following table displays the recommended (battery cable, Fuse, Battery Capacity)
per inverter type :
Inverter type
Input Voltage
DC Battery Cable
Fuse
Battery Capacity
300W
12V
4
mm²
(1*Red/1*Bla
ck)
40
A*1
≥
50Ah
24V
2.5
mm²
(1*Red/1*Black)
20A*1
≥
25Ah
48V
2.5
mm²
(1*Red/1*Black)
10A*1
≥12A
h
500W/600W
12V
6
mm²
(1*Red/1*Black)
40A*2
≥10
0Ah
24V
4
mm²
(1*Red/1*Black)
40A*2
≥
50Ah
48V
2.5
mm²
(1*Red/1*Black)
10A*
2
≥
25Ah
1000W
12V
10
mm²
(1*Red/1*Bla
ck)
40A*4
≥16
0 Ah
24V
6
mm²
(1*Red/1*Black)
20A*4
≥
80Ah
48V
4
mm²
(1*Red/1*Black)
10A*4
≥
40Ah
1500W
12V
10
mm²
(2*Red/2*Black)
40A*6
≥
250Ah
24V
6
mm²
(2*Red/2*Black)
20A*6
≥125
Ah
48V
4
mm²
(2*Red/2*Black)
10A*6
≥
60Ah