Compatibility
Model
Batteries supported
Battery Type
SCHG3
PowerBook G3 Series only
Li-Ion
SCH3400
PowerBook 3400
Li-Ion
PowerBook 3500, G3
Li-Ion
PowerBook 5300
NiMH
PowerBook 190
NiMH
SCH1400
PowerBook 1400 only
NiMH
SCH5000
PowerBook 5300
Li-Ion, NiMH
PowerBook 190
NiMH
SCH500
PowerBook 500
NiMH
For the Charger 500
Charging Modes:
Yellow: The yellow light remains on during all charge phases. The charger
charges one battery at a time, indicated by a solid yellow light. If two
batteries are inserted, a flashing yellow light will indicate which battery
is waiting to charge. When the battery is fully charged, the yellow light
flashes with all four green lights remaining on continuously.
Green: The four green lights indicate percentage charged.
Red: A red light indicates a battery error.
Conditioning:
Conditioning takes slightly longer than just charging and is required occasionally
to eliminate the memory effect. Conditioning completely discharges the
battery and then fully charges it. The most efficient way to condition the
battery is to remove the empty or nearly empty battery from the PowerBook,
insert it in the Charger and press the conditioning button. When the button
is depressed, the red light will go on and the yellow charging light will go off.
If the battery is more than 25% charged when placed in the Charger, the user
will need to press the conditioning button for about three seconds to initiate
the discharge process.
Recalibration:
Note: Recalibration includes a conditioning cycle.
VST Charger
Recalibration is recommended approximately once per month and includes a
conditioning cycle. Recalibration takes longer than charging and conditioning
alone. To recalibrate a battery, insert it into the Charger and wait until it is fully
charged (all four green lights will be on and the yellow light will be flashing),
then press and hold the button for approximately three seconds. The red light
will come on and the other lights will go off. Do not disturb the battery and
Charger during the recalibration process. The recalibration process takes about
4-4.5 hours per battery.
Summary of Contents for SCHG3
Page 1: ...VST Charger...