Technical Data: 

 

Nominal Voltage: 

12 V, 24 V  

Operating Voltage Range: 

8...32 V  

Current Consumption: 

6...60 mA, depending on illumination 

Display Unit (LC Display): 

 

Technology: 

LC Display with specific segments,  
legible with and without illumination, 
Membrane Keyboard with LED Background Illumination 

Presentation Surface: 

49 x 28 mm 

Illumination: 

white LED 

Dimensions (mm): 

200 x 65 x 28 

Assembly Dimensions Opening Electronic System (mm): 

approx. 185 x 57 

Weight: 

approx. 175 g 

Ambient Conditions, Humidity of Air: 

max. 95 % RH, no condensation 

 

 

 

Declaration of Conformity: 

In accordance with the provisions of Directives 2014/35/EU, 2014/30/EU, 2009/19/EC, this 

product complies with the following standards or normative documents: 

EN55014-1;  EN55022 B;  EN61000-6-1;  EN61000-4-2;  EN61000-4-3;  EN61000-4-4;   

EN62368-1;  EN50498.

 

 

The product 

must not be 

disposed of in 

the household 

waste. 

 

The product is RoHS compliant. 

It complies with the directive 

2011/65/EU for Reduction of 

Hazardous Substances in electrical 

and electronic equipment. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Delivery Scope: 

Available Accessories: 

 

1 Pc.   VPC Terra Display and Control Panel 

Switch Unit 40 

Order No. 2071 

4 Pcs. Fastening Screws 

Switch Unit 100 

Order No. 2072 

1 Pc.   6-pole Modular Cable, 5 m length 

Various VOTRONIC Tank Measuring Sensors 

 

2 Pcs. Connecting Terminal 

 

 

1 Pc.   Drilling Jig 
1 Pc.   Operating Manual 

 

 

 

 

 

 

Subject to misprints, errors and technical modification without notice. 
All rights reserved, particularly the right of reproduction. Copyright 

 VOTRONIC 01/2019. 

Made in Germany by VOTRONIC Elektronik-Systeme GmbH, Johann-Friedrich-Diehm-Str. 10, D-36341 Lauterbach  

Tel.: +49 (0)6641/91173-0 Fax: +49 (0)6641/91173-20 E-Mail: [email protected] Internet: www.votronic.de 

 

Summary of Contents for VPC Terra

Page 1: ...l free output Solar Computer Suitable for all VOTRONIC solar charging controllers since year of production 2014 Instantaneous solar power in W Instantaneous solar current in A Charged solar capacity in Ah Charged solar power in kWh Please read the installation instructions operating manual and safety instructions page 7 completely prior to starting connection and placing the unit into operation Th...

Page 2: ...nic system and full utilization of the storage space which might be located behind Solar Controller The VOTRONIC Solar Controller is connected directly at the display panel by a plug and go 6 pole data cable see available accessories Tank Sensors A VOTRONIC tank sensor with continuous output signal is to be installed at the corresponding tank according to the installation instructions The connecti...

Page 3: ...tput max 1 A The output serves as control signal for an external controllable main switch Switch Unit The main switch can be operated from the display panel In addition the system provides an automatic disconnection in case of overvoltage or low voltage Battery Protector Function In active condition ON the battery voltage 12 V or 24 V is at disposal here The output is protected from overload by a ...

Page 4: ...mination can also be switched off manually by shortly pressing the main switch see figure on the left side The brightness of the LED lamps is coupled with the illumination of the display If the display is dark the LED lamps will also be dimmed to a minimum Brightness Display and LED The brightness of the display illumination and the LED lamps can be changed at any time by pressing and holding 3 se...

Page 5: ...After initial start up the nominal capacity of the system must be adjusted at the solar computer to ensure correct display of the capacity Set the display manually to 100 when the sun is shining and the full charging current is flowing Adjustment is effected by setting the display to current A and by pressing the key Solar for more than 3 seconds until Set 100 is displayed This procedure can be re...

Page 6: ...ssing and holding the arrow keys After the last menu item the display returns to normal operating mode Menu Items At each menu item the symbol Set will be displayed at the upper edge of the menu Board battery disconnection threshold in V Board battery start threshold in V Activation deactivation audible alarm device The audible alarm can generally be activated or deactivated On or Off will be disp...

Page 7: ...r work on the electric system If the user is not able to draw from the manual which characteristic values are valid for a unit or which regulations are to be observed a specialist is to be consulted The user buyer is responsible for the observation of construction and safety regulations of any kind Keep children away from the batteries Observe the safety regulations of the battery manufacturer The...

Page 8: ...000 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in the household waste The product is RoHS compliant It complies with the directive 2011 65 EU for Reduction of Hazardous Substances in electrical and electronic equipment Delivery Scope Available Accessories 1 Pc VPC Terra Display and Control Panel Switch Unit 40 Order No 2071 4 Pcs Fastening Screws ...

Reviews: