- 6 - 

 

The  connections  at  the  smart  shunt  should  always  be  tightened  firmly  to  avoid  any  transition 
resistance. Permanent high load might result in heating of the smart shunt. 
Except  of  the  smart  shunt,  no  further  connection  (e.  g.  of  consumers  or  charging  devices)  should 

exist at the negative pole of the battery or at the negative pole of the complete battery system! 
 
The terminal of the smart shunt supplies 300 mA and serves for control of a Votronic Switch Unit. These units 
are relays for high current rates, which do not require any current for holding, thus avoiding an unnecessary 
load of the battery. Remote control of the terminal is effected from the panel. Thus, it can be switched-off and 
switched-on  manually.  Furthermore,  an  automatic  disconnection  is  possible,  when  dropping  below  the 
adjusted residual capacity or battery voltage (protection against deep discharge). 
 

Display and Control Panel (Display Panel) 

Choose a central and easily accessible location in the living area for installation of the display panel. This will 
facilitate the legibility of the information and the operation of the functions. The clear width of the cutout is at 
least 184 x 57 mm.  
If  possible,  the  rear  cutout  opening  should  be  covered  with  electrically  nonconducting  material  to  ensure 
efficient protection of the electronic system and full utilization of the storage space, which might be located 
behind. Ensure the ventilation of the electronic system.  
 
The display panel will be connected to the smart shunt via a 6-pole control cable. The connection is executed 
ready to be plugged in, and the cable should be laid according to the safety instructions.  
 
Supply of the display panel including USB charging socket and pump relay is effected directly from the battery.  
The temperature sensors, as well as the optional tank sensors use the delivered 5-pole distribution terminal as 
common minus connection. For this terminal, the wire-ends must be stripped for a length of 11 mm. 
 

Water Pump 

The relay contact for the water pump is switched by a key at the display. The maximum admissible load of the 
output is 16 A. 
 

Outside Temperature Sensor 

Install the delivered temperature sensor for outside temperature at a protected 
location, if possible below the  vehicle. Ensure  that the  installation place  is not 
influenced by any source of heat (hot exhaust, asphalt etc.). Should the length 
of  the  connection  cable  at  the  temperature sensor  be  not  sufficient,  it  can  be 
extended to the desired length by a cable of min. 0.75 mm².  
The  temperature  sensors  are  protected  against  reverse  battery  and  can  be 
connected with any polarity. 
 

Inside Temperature Sensor 

For  installation,  remove  the  cap  from  the  temperature 
sensor  and  insert  the  sensor  with  the  cable  from  behind 
through  the  mounting  hole  (7.5  mm).  Reinsert  the  cap  on 
the sensor after that and push both into the mounting hole 
from  the  front.  The  temperature  sensors  are  protected 
against  reverse  battery  and  can  be  connected  with  any 
polarity.  
 

Tank Sensors 

As  option,  up  to  two  Votronic  Tank  Sensors  can  be  connected  and  used.  All  Votronic  Tank  Sensors  of  the 
product category "Mobile Leisure Time" are compatible. The connections of the tank sensors are to be coupled 
to the display panel, as indicated in the connection plan. The cross-section of the cables should be min. 0.75 
mm².  The  current  supply  to  the  tank  sensors  by  the  panel  is  restricted  to  the  time,  in  which  the  levels  are 
interrogated.  
 

 

Summary of Contents for VPC Jupiter 100

Page 1: ...artphones or tablets Battery Computer for the Board Battery Voltage in V Battery current in A Battery capacity in and Ah Remaining time in h Undervoltage protection Voltage of the starter battery in V Solar computer Suitable for all VOTRONIC Solar Charging Controllers also VBCS Tripe from year of construction 2014 Instantaneous solar power in W Instantaneous solar current in A Charged solar capaci...

Page 2: ...y It will be turned off automatically after 3 minutes if the main switch is switched on If the main switch is switched off the illumination will be turned off already after 20 seconds to avoid an unnecessary load of a possibly empty battery The illumination can also be switched off manually by shortly pressing the main switch see figure on the left side The brightness of the LED lamps is coupled w...

Page 3: ...ntroller is in stand by mode Full sun Solar power is at disposal maximum possible charge Flashing sun The controller limits the current because of a full or almost full battery to avoid battery overcharging For determination of the possible solar power the battery must be discharged by a consumer such as lighting until the solar controller stops limiting the current and the sun symbol stops flashi...

Page 4: ...ng formula Capacity switching off threshold actual capacity actual current If the battery does not supply current a calculation of the remaining time is of course not possible Now the sign will be displayed Battery Protector Combined with a remote controlled main switch e g Switch Unit 100 the VPS Jupiter system has an integrated protection against deep discharge which can be adjusted individually...

Page 5: ...terminal for control of a main switching relay such as the Votronic Switch Unit 40 Any battery current should flow over the smart shunt Therefore it is to be installed directly near the battery batteries Correct calculation of the actual battery capacity is only possible if all currents are detected correctly by the smart shunt Ground straps at the connecting screws M8 of the smart shunt are to be...

Page 6: ...ding to the safety instructions Supply of the display panel including USB charging socket and pump relay is effected directly from the battery The temperature sensors as well as the optional tank sensors use the delivered 5 pole distribution terminal as common minus connection For this terminal the wire ends must be stripped for a length of 11 mm Water Pump The relay contact for the water pump is ...

Page 7: ... value 220 Ah must be set After the basic setting the battery must be charged using a suitable charger in case of mobile homes using the existing board charger for a duration of 24 h This is absolutely required so that the battery computer is able to recognize 100 full charging required for starting If the smart shunt loses its voltage supply battery disconnected etc also proceed as described abov...

Page 8: ... C20 Adjustment Type Board Battery The value to be set can be drawn from the table of the battery types If an inadmissible type is set and when changing to the next page the display jumps to the last admissible value The displays are flashing alternately Board battery disconnection threshold low voltage in V Board battery start threshold in Board battery disconnection threshold in Activation Deact...

Page 9: ...rk on the electric system If the user is not able to draw from the manual which characteristic values are valid for a unit or which regulations are to be observed a specialist is to be consulted The user buyer is obliged to observe any construction and safety regulations Except of the smart shunt no further connection such as of consumers should exist at the negative pole of the battery or at the ...

Page 10: ... 10 Notes ...

Page 11: ...ondensation Display Unit LCD Display Technology LC Display with specific segments legible with and without illumination Membrane keyboard with LED background illumination Representation Surface 49 x 28 mm Lighting white LED Dimensions 200 x 75 x 30 mm Assembly Dimensions Opening Electronic System approx 185 x 57 mm Weight approx 200 g Smart Shunt 100 A 200 A 400 A Max Admissible current Smart Shun...

Page 12: ...nce with the provisions of Directives 2014 35 EU 2014 30 EU 2009 19 EC this product complies with the following standards or normative documents EN55014 1 EN55022 B EN61000 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in the household waste The product is RoHS compliant It complies with the directive 2011 65 EU for Reduction of Hazardous Substances ...

Reviews: