Votronic VPC Jupiter 100 Installation And Operating Manual Download Page 10

- 10 - 

 

Notes: 

 

Summary of Contents for VPC Jupiter 100

Page 1: ...artphones or tablets Battery Computer for the Board Battery Voltage in V Battery current in A Battery capacity in and Ah Remaining time in h Undervoltage protection Voltage of the starter battery in V Solar computer Suitable for all VOTRONIC Solar Charging Controllers also VBCS Tripe from year of construction 2014 Instantaneous solar power in W Instantaneous solar current in A Charged solar capaci...

Page 2: ...y It will be turned off automatically after 3 minutes if the main switch is switched on If the main switch is switched off the illumination will be turned off already after 20 seconds to avoid an unnecessary load of a possibly empty battery The illumination can also be switched off manually by shortly pressing the main switch see figure on the left side The brightness of the LED lamps is coupled w...

Page 3: ...ntroller is in stand by mode Full sun Solar power is at disposal maximum possible charge Flashing sun The controller limits the current because of a full or almost full battery to avoid battery overcharging For determination of the possible solar power the battery must be discharged by a consumer such as lighting until the solar controller stops limiting the current and the sun symbol stops flashi...

Page 4: ...ng formula Capacity switching off threshold actual capacity actual current If the battery does not supply current a calculation of the remaining time is of course not possible Now the sign will be displayed Battery Protector Combined with a remote controlled main switch e g Switch Unit 100 the VPS Jupiter system has an integrated protection against deep discharge which can be adjusted individually...

Page 5: ...terminal for control of a main switching relay such as the Votronic Switch Unit 40 Any battery current should flow over the smart shunt Therefore it is to be installed directly near the battery batteries Correct calculation of the actual battery capacity is only possible if all currents are detected correctly by the smart shunt Ground straps at the connecting screws M8 of the smart shunt are to be...

Page 6: ...ding to the safety instructions Supply of the display panel including USB charging socket and pump relay is effected directly from the battery The temperature sensors as well as the optional tank sensors use the delivered 5 pole distribution terminal as common minus connection For this terminal the wire ends must be stripped for a length of 11 mm Water Pump The relay contact for the water pump is ...

Page 7: ... value 220 Ah must be set After the basic setting the battery must be charged using a suitable charger in case of mobile homes using the existing board charger for a duration of 24 h This is absolutely required so that the battery computer is able to recognize 100 full charging required for starting If the smart shunt loses its voltage supply battery disconnected etc also proceed as described abov...

Page 8: ... C20 Adjustment Type Board Battery The value to be set can be drawn from the table of the battery types If an inadmissible type is set and when changing to the next page the display jumps to the last admissible value The displays are flashing alternately Board battery disconnection threshold low voltage in V Board battery start threshold in Board battery disconnection threshold in Activation Deact...

Page 9: ...rk on the electric system If the user is not able to draw from the manual which characteristic values are valid for a unit or which regulations are to be observed a specialist is to be consulted The user buyer is obliged to observe any construction and safety regulations Except of the smart shunt no further connection such as of consumers should exist at the negative pole of the battery or at the ...

Page 10: ... 10 Notes ...

Page 11: ...ondensation Display Unit LCD Display Technology LC Display with specific segments legible with and without illumination Membrane keyboard with LED background illumination Representation Surface 49 x 28 mm Lighting white LED Dimensions 200 x 75 x 30 mm Assembly Dimensions Opening Electronic System approx 185 x 57 mm Weight approx 200 g Smart Shunt 100 A 200 A 400 A Max Admissible current Smart Shun...

Page 12: ...nce with the provisions of Directives 2014 35 EU 2014 30 EU 2009 19 EC this product complies with the following standards or normative documents EN55014 1 EN55022 B EN61000 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in the household waste The product is RoHS compliant It complies with the directive 2011 65 EU for Reduction of Hazardous Substances ...