Water Pump: 

The  pump  key  switches  the  pump  relay  on  or  off.  The  state  of  the  relay  is  indicated  by  the 
adjacent LED. Operation of the pump is only possible, if the main switch had been switched-on. 
It  will  be  switched-off  automatically,  as  soon  as  the  main  switch  had  been  switched-off.  The 

pump cannot be switched-on, if the main switch had been switched-off.  
 

Solar Computer: 

 

 

 

 

 

 

 

 

 

 

The Solar Computer indicates the current operating state, the solar current, as well as the 
solar power of the connected VOTRONIC Solar Controller. In addition, it is equipped with a 
solar power meter.  
Use the arrow keys     on the right side of the display to change to the next or previous 
page. 

Current: 

The instantaneous current rate in Amperes (A) is displayed. 

 
Capacity:

 The instantaneous capacity in Watts (W) of the solar system is displayed. 

 
Solar  Power  Meter:

  The  power  being  generated  by  the  solar  system  is  measured 

continuously and will be displayed as ampere-hours (Ah), as well as watt-hours (Wh). If the 
value 9999 Wh is exceeded, the display changes automatically to kWh. The meter readings 
can  be  separately  reset  to  zero  at  any  time.  Reset  can  be  effected,  if  the  corresponding 
meter value is displayed and by pressing the key Solar    for more than 3 seconds until (Set 
----) is displayed. 
 

Operating State Solar Controller:

 

Depending on the solar controller, the operating state of the solar controller is indicated by 
the sun symbol.  

-

 

No sun: Solar power is not at disposal; the solar controller is in stand-by mode. 

-

 

Full sun: Solar power is at disposal, maximum possible charge 

-

 

Flashing sun: The controller limits the current because of a full or almost full battery to 
avoid battery overcharging. For determination of the possible solar power, the battery 
must  be  discharged  by  a  consumer  (such  as  lighting)  until  the  solar  controller  stops 
limiting the current and the sun symbol stops flashing. 

 
Thermometer/Clock: 

 

 

 

 

 

The thermometers indicate the inside and outside temperature.  
Press the key "Thermometer/Clock" to change between inside and outside temperature or 
clock.  
 
The time is displayed in 24 hours format.  
Setting of the time is effected by pressing the key "Thermometer/Clock"  for 3 seconds, 
until "Set" will be displayed at the upper edge of the display, and the hours of the time will 
be  flashing.  Use  the  arrow  keys   

 

  to  set  the  hours.  Shortly  press  the  key 

"Thermometer/Clock"    to set the minutes. The minutes will now be flashing and can be 
changed using the arrow keys      .  
 

Tank Displays: 

 

 

 

The  tank  displays  indicate  the  levels  (level  height)  of  the  fresh  water  and  sewage  water 
tank as percentage.  
Use the key "Tank" to switch between the display for fresh water tank and sewage water 
tank. If the sensors had not been connected or are wrongly connected, the corresponding 
tank display cannot be selected.  
Current  will  only  be  supplied  to  the  tank  sensors,  if  the  levels  will  be  interrogated  by  a 
keystroke.  If  the  illumination  of  the  display  is  switched-off  manually,  or  if  it  switches-off 
itself  after  a  certain  time,  the  display  changes  automatically  to  the  actual  time.  Thus,  an 
unintended operation of the sensors and current consumption is avoided.  

 

 

Summary of Contents for VPC Jupiter 100

Page 1: ...artphones or tablets Battery Computer for the Board Battery Voltage in V Battery current in A Battery capacity in and Ah Remaining time in h Undervoltage protection Voltage of the starter battery in V Solar computer Suitable for all VOTRONIC Solar Charging Controllers also VBCS Tripe from year of construction 2014 Instantaneous solar power in W Instantaneous solar current in A Charged solar capaci...

Page 2: ...y It will be turned off automatically after 3 minutes if the main switch is switched on If the main switch is switched off the illumination will be turned off already after 20 seconds to avoid an unnecessary load of a possibly empty battery The illumination can also be switched off manually by shortly pressing the main switch see figure on the left side The brightness of the LED lamps is coupled w...

Page 3: ...ntroller is in stand by mode Full sun Solar power is at disposal maximum possible charge Flashing sun The controller limits the current because of a full or almost full battery to avoid battery overcharging For determination of the possible solar power the battery must be discharged by a consumer such as lighting until the solar controller stops limiting the current and the sun symbol stops flashi...

Page 4: ...ng formula Capacity switching off threshold actual capacity actual current If the battery does not supply current a calculation of the remaining time is of course not possible Now the sign will be displayed Battery Protector Combined with a remote controlled main switch e g Switch Unit 100 the VPS Jupiter system has an integrated protection against deep discharge which can be adjusted individually...

Page 5: ...terminal for control of a main switching relay such as the Votronic Switch Unit 40 Any battery current should flow over the smart shunt Therefore it is to be installed directly near the battery batteries Correct calculation of the actual battery capacity is only possible if all currents are detected correctly by the smart shunt Ground straps at the connecting screws M8 of the smart shunt are to be...

Page 6: ...ding to the safety instructions Supply of the display panel including USB charging socket and pump relay is effected directly from the battery The temperature sensors as well as the optional tank sensors use the delivered 5 pole distribution terminal as common minus connection For this terminal the wire ends must be stripped for a length of 11 mm Water Pump The relay contact for the water pump is ...

Page 7: ... value 220 Ah must be set After the basic setting the battery must be charged using a suitable charger in case of mobile homes using the existing board charger for a duration of 24 h This is absolutely required so that the battery computer is able to recognize 100 full charging required for starting If the smart shunt loses its voltage supply battery disconnected etc also proceed as described abov...

Page 8: ... C20 Adjustment Type Board Battery The value to be set can be drawn from the table of the battery types If an inadmissible type is set and when changing to the next page the display jumps to the last admissible value The displays are flashing alternately Board battery disconnection threshold low voltage in V Board battery start threshold in Board battery disconnection threshold in Activation Deact...

Page 9: ...rk on the electric system If the user is not able to draw from the manual which characteristic values are valid for a unit or which regulations are to be observed a specialist is to be consulted The user buyer is obliged to observe any construction and safety regulations Except of the smart shunt no further connection such as of consumers should exist at the negative pole of the battery or at the ...

Page 10: ... 10 Notes ...

Page 11: ...ondensation Display Unit LCD Display Technology LC Display with specific segments legible with and without illumination Membrane keyboard with LED background illumination Representation Surface 49 x 28 mm Lighting white LED Dimensions 200 x 75 x 30 mm Assembly Dimensions Opening Electronic System approx 185 x 57 mm Weight approx 200 g Smart Shunt 100 A 200 A 400 A Max Admissible current Smart Shun...

Page 12: ...nce with the provisions of Directives 2014 35 EU 2014 30 EU 2009 19 EC this product complies with the following standards or normative documents EN55014 1 EN55022 B EN61000 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in the household waste The product is RoHS compliant It complies with the directive 2011 65 EU for Reduction of Hazardous Substances ...

Reviews: