"D+":

 

Control input charging converter ON / OFF and function selection:

 

Two (2) operating modes for automatic ON / OFF control of the unit are possible: 

1)

   Connection of terminal "D+"

Activation of the charging converter by control signal of the vehicle:

 

This operating mode is to be used for the caravan living compartment via plug connections, for conventional 
generators/vehicles, as well as for 

EURO standard 6, 6+ vehicles 

with energy management, start/stop, strongly 

varying voltages of generator/STARTER batteries during energy recovery etc. Also refer to the connection plan, page 2. 

Advantageous for stable operation, even with long cables between STARTER battery and charging converter in 
connection with conventional generators. 

 

Increase of the charging capacity *: 

11.70 V

   

Reduction of the charging capacity *:  

11.40 V

   

Switching off threshold (with continuous signal "D+") *: < 

11.20 V

   with delay 30 s 

Recharging branch

 for STARTER battery (trickle charging), if the BOARD battery is charged by a mains supply charger: 

ACTIVE 

2)

   No connection of terminal "D+". It is left blank: Pure voltage control of the charging converter: 

The unit is activated by the increased voltage at the STARTER battery due to the running engine. It will be switched off 
automatically in case of a voltage drop (engine off). 
This operating mode requires powerful, short cables to the STARTER battery and a conventional,  
 a non-intelligent generator with sufficient high and uniform charging voltage (not Euro 6).  

During this operating mode the STARTER battery cannot be discharged, due to the high switching off threshold. 

Note:  

If voltage had been supplied to the terminal "D+" by mistake, the unit will memorize this "control by signal D+" and will expect this 
signal for the further operation. 
Reset: 

Return to the operating mode "Voltage Control" (without "D+") is possible by

 

separating the unit from any 

operating voltage for 30 seconds. (Separate BOARD and STARTER battery).

 

Increase of the charging capacity *: 

> 13.30 V 

Reduction of the charging capacity *:  

< 13.00 V 

Switching off threshold*: 

< 12.90 V

   with delay 30 s 

Recharging branch

 for STARTER battery (trickle charging), if the BOARD battery is charged by a mains supply charger: 

BLOCKED 

* Also see "Function of the Power Control at STARTER Battery and Generator", page 7. 

Battery Temperature Sensor: 

Connect the temperature sensor (included in the standard delivery scope) to the 

terminals "TS   TS"

 (any polarity).  

The temperature sensor controls the 

temperature 

of the BOARD supply 

battery

.

 

 

Ensure that the installation place of the sensor is not influenced by any source of heat (engine heat, exhaust, heater 
etc.)! 

Lead-Acid, Gel, AGM Batteries: 

Installation: 

The 

thermal contact

 of sensor and 

battery inside temperature should be well.

 Thus, it should be screwed 

down to the negative pole or positive pole of the battery. It is also possible to fasten it at the sidewall centre of the battery 
casing.

 

Function: 

The temperature-dependent charging voltage of the BOARD battery will be adapted automatically to the battery 

temperature (automatic temperature equalization).

 

For this purpose, the temperature sensor measures the battery 

temperature. In case of low temperatures (winter operation), the charging voltage will be increased in order to improve 
and accelerate full charging of the weak battery. Sensitive consumers are protected by a voltage limitation in case of very 
low outside temperatures. 

 

In case of summery temperatures, the charging voltage is reduced to minimize the load (gassing) of the battery and to 
extend the lifetime of gas-tight batteries.

 

Battery Protection:

 In case of excessive battery temperatures (from +50 °C), the charging voltage will be reduced strongly 

to the 

safety charging voltage

 of approx. 12.80 V for battery protection, and the maximum charging current rate will be 

halved

 

(safety mode, LED 

"Charge" is flashing

). Any charging data being recorded hitherto will be kept in memory. Battery 

charging is then interrupted, but the supply of possibly connected consumers will be continued by the unit, and the battery 
is allowed to cool down. After that, automatic charging will be resumed. Also refer to:

 

 

"Lead batteries, 3 charging programs

, charging voltage rates and 

temperature equalization" 

from 

page 8. 

The unit recognizes automatically a missing sensor, cable break or short circuit of the sensor cables, as well as unreasonable 
measuring values. In that case, it will switch automatically to the usual charging voltage rates of 20 °C / 25 °C being 
recommended by the battery manufacturers.

 

 

Summary of Contents for VCC 1212-20 C

Page 1: ...charging characteristic line The charging converter excels by its compact design low weight high frequency switch mode boost and buck converter technology and powerfully dimensioned power components for safe operation The simultaneously supplied 12 V consumer loads are protected against overvoltage and voltage fluctuations The integrated recharging branch 12 V 0 1 A provides charging trickle charg...

Page 2: ...ff by the switched 12 V signal No 10 During extended standstill periods and charging of the BOARD battery mains solar the recharging branch of the VCC 1212 20 C 12 V 0 1 A can be used for trickle charging of the vehicle s STARTER battery The 12 V heating cartridge of the refrigerator can be connected to the connector No 10 and 11 during driving while the supply of the refrigerator control is taken...

Page 3: ...led also refer to Function Selection page 5 2 During extended standstill periods and charging of the BOARD battery the recharging branch of the VCC 1212 20 C 12 V 0 1 A is used for trickle charging of the vehicle s STARTER battery Reverse battery 12 V mix up at the large power terminals IN 12 V and OUT 12 V must be avoided in any case This will result in serious damage of the unit Observe the cros...

Page 4: ...rip i e Terminal D 1 Connect it automatic unit control via signal vehicle D 2 Not used automatic unit control via operating voltage Further description function selection see page 2 Unit Settings d Imperatively set the charging program for the BOARD battery type design technology acid gel AGM LiFePO4 from page 8 Start up and Function Test e Further description see page 7 Further operation of the u...

Page 5: ...d by a mains supply charger BLOCKED Also see Function of the Power Control at STARTER Battery and Generator page 7 Battery Temperature Sensor Connect the temperature sensor included in the standard delivery scope to the terminals TS TS any polarity The temperature sensor controls the temperature of the BOARD supply battery Ensure that the installation place of the sensor is not influenced by any s...

Page 6: ...re equipped with a power limit function allowing to reduce the charging capacity temporarily at the touch of a button see technical data LED Remote Control S Order No 2076 7 LEDs for convenient control of functions and charging state LCD Charge Control S VCC Order No 1248 With illuminated excellently readable display showing the state of the charging converter the current charging phase the voltag...

Page 7: ...ery 12 V The unit is equipped with a charging branch which ensures support charging and trickle charging of the STARTER battery 12 V in case of extended standstill periods It will be activated automatically as soon as the BOARD battery had been sufficiently charged for instance by a mains supply charger see Technical Data Recharging Branch A small part of the charger current approx 0 1 A is divert...

Page 8: ... 1 Lead Acid AGM 1 Switch Position U1 14 40 V U2 13 50 V 2 6 h Universal charging program for acid lead acid batteries acc to DIN 57 510 VDE 0510 for charging and trickle charging of supply BOARD batteries Ensures short charging times high charging factor and acid mixing for open standard batteries and closed SLA low maintenance maintenance free non solid electrolyte lead acid drive lighting solar...

Page 9: ...s balancing as well as safety circuit is not admissible The battery temperature sensor must be installed at the battery screw to the negative pole and must be connected at the unit It serves as protection for the battery No function without temperature sensor The LEDs Batt Full and Power are flashing simultaneously If possible the battery temperature should be kept above 0 C 4 LiFePO4 14 4 V Switc...

Page 10: ...he battery charging current is decreased slowly while full charging is increasing The charging converter controls the charging time as well as the charging current From these values and from the course of charging being recorded during the phase I the charging converter determines the 100 full charge point of the battery for automatic switching to U2 In contrast to conventional voltage transformer...

Page 11: ...ee from condensation water Never use the unit in locations where the risk of gas or dust explosion exists Open air operation of the unit is not allowed Lay the cables in a way that damages are excluded and observe to fasten them tightly Never lay 12 V cables and 230 V mains supply cables into the same cable conduit empty conduit Check live cables or leads periodically for insulation faults points ...

Page 12: ... OFF 13 0 V Active at LiFePO4 Board Battery Voltage ON 13 5 V OFF 13 4 V Input TS TS for Battery Temperature Sensor BOARD Yes Quiescent Current Standby 3 7 mA Charging Timer 3 fold Ripple Factor Voltage 30 mV rms Limit of Charging Voltage OUT BOARD Consumer Protection 15 00 V Safety Protection against Short circuit Back Discharge Yes Fitting Position of Unit any Temperature Range 20 45 C Speed con...

Reviews: