15 -

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Safety Regulations and Appropriate Application: 

The charger has been designed according to the valid safety regulations. 

  

Appropriate application is restricted to: 

 

1.

 

Charging of lead-gel, lead-AGM, lead-acid or LiFePO4 complete batteries (with integrated BMS, balancing, 
safety circuit and approval!)  Charging of batteries of the indicated nominal voltage and simultaneous 
supply of the consumers being connected to these batteries in fixed installed systems with the indicated 
battery capacities and charging programs. 

2.

 

Connection to a shock-proof socket, which has been installed according to the valid technical regulations, 
protected with max. 16 A (if required mobile/stationary with a fault current breaker (FI) with a nominal 
residual current of 30 mA). 

3.

 

Connection in consideration of the indicated cable cross-sections at the charging ports. 

4.

 

Fuses of the indicated capacity are to be provided near the battery to protect the cabling between 
battery and charger output.  

5.

 

Technically faultless condition. 

6.

 

Installation in a well-ventilated room, protected from rain, humidity, dust, aggressive battery gases, as 
well as in an environment being free from condensation water. 

 

Never use the unit in locations where the risk of gas or dust explosion exists! 

 

 

Open-air operation of the unit is not allowed.

 

 

Lay the cables in a way, that damages are excluded and observe to fasten them tightly.

 

 

Never lay 12 V (24 V) cables and 230 V mains supply cables into the same cable conduit (empty conduit).

 

 

Check live cables or leads periodically for insulation faults, points of break, as well as loosened or overloaded 
connections and remedy possible defects. 

 

The unit is to be disconnected from any connection prior to execution of electrically welding or work on the 
electric system. 

 

If the user is not able to draw from the manual, which characteristic values are valid for a unit or which 
regulations are to be observed, a specialist is to be consulted. 

 

The user / buyer is responsible for the observation of construction and safety regulations of any kind. 

 

The unit does not contain any parts, which can be replaced by the user.

 Even after withdrawal of the mains 

plug, the unit may be 

extremely live

 for an extended period (particularly in case of failure). 

 

Keep children away from the charger and the batteries. 

 

Observe the safety regulations of the battery manufacturer; deaerate the battery room. 

 

Non-observance may result in injury or material damage. 

 

The warranty period is 36 months from the purchase date (against presentation of the sales slip or invoice). 

 

The warranty will be void in case of any inappropriate utilisation of the unit, if it is used beyond the technical 
specification, in case of improper operation or external intervention. We do not assume any liability for any 
damage resulting hereof. The liability exclusion is extended to any service being executed by third, which has 
not been ordered by us in writing. Service is to be effected exclusively by VOTRONIC Lauterbach. 

Summary of Contents for VAC 1215 M 3A

Page 1: ...f 50 80 which is advantageous for the battery lifetime Simultaneous floating of 12 V consumer loads such as alarm systems WLAN etc as well as the vehicle s starter battery see page 5 2 Main Battery II...

Page 2: ...nd hard mounting surface which is protected from moisture and humidity The unit can be installed in any position Protect the unit from aggressive battery gases Despite the charger s high efficiency he...

Page 3: ...3A VAC 1225 M3A VAC 1230 M 3A 2 5 mm 2 2x 3x 0 6 2 0 m 2x 3x 0 5 1 3 m 4 mm 2 2x 3x 1 5 3 2 m 2x 3x 0 8 2 0 m 2x 3x 0 6 1 6 m 2x 3x 0 5 1 3 m 6 mm 2 2x 3x 2 5 4 8 m 2x 3x 1 1 3 0 m 2x 3x 0 9 2 4 m 2x...

Page 4: ...tion For this purpose the temperature sensor measures the battery temperature In case of low temperatures winter operation the charging voltage will be increased in order to improve and accelerate ful...

Page 5: ...n in case inadvertently of power failure engine start higher charging of the battery batteries by the solar system high 12 V consumer current rates etc in the meantime Of course the temperature contro...

Page 6: ...for acid lead acid batteries acc to DIN 57 510 VDE 0510 for charging and trickle charging of supply board batteries Ensures short charging times high charging factor and acid mixing for open standard...

Page 7: ...attery manufacturer also recommended for batteries in round cell technology such as EXIDE MAXXIMA DC Charging Programs 5 8 9 for LiFePO4 Batteries 5 Charging characteristic lines charging voltage rate...

Page 8: ...d safety circuit and integrated BMS as well as Super B SB12Vxx E GNB Exide SL12 xxxHC with BMS of the indicated capacity rates Operation of the battery only with own BMS and prescribed safety circuit...

Page 9: ...he temperature equalization for battery I will also be applied to battery II Note If required the vehicle s starter battery is to be connected to the auxiliary port III 12 V 2 A 3A Charging program fo...

Page 10: ...longer and turns off shortly approx every 1 5 sec only with charging programs LiFePO4 Li battery protection battery temperature below 0 C the charging current might be reduced for protection of the Li...

Page 11: ...rmines the 100 full charge point of the battery for automatic switching to U2 In case of slightly discharged batteries the duration of phase U1 will be kept short for relief of the battery and low mai...

Page 12: ...tery has been deeply discharged In case of insufficient charging the charging process has been interrupted too often already during the charging phase I or U1 the charging process has not been complet...

Page 13: ...imitation Charging voltage limitation to max 15 0 V during all charging modes to protect sensitive consumers Overload Overheating Protection Charger The charger is equipped with a double electronic pr...

Page 14: ...g Phase I U1 U2 Yes Yes Yes Yes Lead Battery Regeneration at extended down time 2x week 1 h Yes Yes Yes Yes LiFePO4 Auto Wake Up in case of extended down time every 10 days 0 5 h Yes Yes Yes Yes or Li...

Page 15: ...y Never lay 12 V 24 V cables and 230 V mains supply cables into the same cable conduit empty conduit Check live cables or leads periodically for insulation faults points of break as well as loosened o...

Page 16: ...following standards or normative documents EN55014 1 EN55022 B EN 61000 3 2 EN 61000 3 3 EN61000 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN 61000 4 6 EN 61000 4 11 EN60335 EN50498 The prod...

Reviews: