background image

- 4 - 

Tank Displays: 

 

The tank level is represented in form of a clearly arranged luminous bar with 10 light-emitting diodes (each) in three colours 
allowing that the tank level can be read conveniently at a glance. Display is effected continuously; intermediate values are 
displayed in variable brightness.  

During  refuelling  and  defuelling  of  the  tanks,  the  continuously  raising  or  dropping  display  shows  a  direct  image  of  the 
instantaneous tank level. 

The fresh water tank display warns in time of an empty water tank. Due to its accuracy it is a very good aid for tank filling. 
Also the sewage water and the feces tank display facilitate immediate disposal, which is appreciated by environment-
conscious users. 

 

 
Level measurement requires installation of a tank transmitter (measuring sensor) at each tank, which must be connected to 
the Info Panel Pro via three cables or two cables (as well as ground/battery minus). 

 

 

* no longer available 

 
Note:

  

All measuring sensors  listed  in the table  supply a continuous  signal and are designed for continuous operation. Thus, their 
design is optimally adapted to an operation at the Info Panel Pro. 

 

Former  measuring  sensors,  such  as  the  Tank  Transmitter  Set,  order  No.  5510,  and  the  Tank  Probe,  order  No.  5520,  work 
according to the conductive measuring method (conductivity). Due to the 7-stage measurement, they are no longer suitable 
for continuous operation at the tank displays S. 

 
 

Operation of the Fresh Water Single Display: 

 

 

When pressing the key, the instantaneous level of the tank will be displayed.  

 

If they key is pressed again, the display is switched-off.  

 

In case of an empty tank, the lowest LED is always lighting dimly at least brightness. 

 

10 minutes after the last activity, the display will be switched-off automatically for reasons of power saving. 

 

Activation of the tank transmitters is effected together with the display.  

 
 

Operation of the Sewage Water / Feces Double Display:

 

 

 

 

When pressing the key, the instantaneous level of the sewage water tank will be displayed. The LED “Sewage 
Water” is lighting.  

 

If the key is actuated for a second time, it will be switched to the feces tank. The LED “Feces Tank” is lighting. 

 

If they key is pressed for a third time, the display is switched-off **.  

 

In case of an empty tank, the lowest LED is always lighting dimly at least brightness. 

 

10 minutes after the last activity, the display will be switched-off automatically for reasons of power saving. 

 

Activation of the tank transmitters is effected together with the display.  

** “Feces Tank” will be completely skipped, if there is no tank transmitter connected!

 

 

Required Measuring Sensors (1 each Tank, for 12 V and 24 V) 

Selection acc. to Tank volume, tank height and installation possibility at the tank:

 

 

Tank Transmitter, 

Measuring Sensor 

Type 

 

Order 

No. 

 

Installation 
at the Tank 

 

Adjustable 

Tank Height in 

cm 

min.    max. 

 

Tank Material 
Pl = Plastic  
Me = Metal 
 

Tank Volume 

 

Tank Electrode 25 

5538 

Top/Bottom 

10 

25 

Pl / Me 

 

 

-- 

Tank Electrode 35* 

5540* 

Top/Bottom 

15 

35 

Pl / Me 

 

 

-- 

Tank Electrode 50 

5542 

Top/Bottom 

20 

50 

Pl / Me 

 

 

-- 

Tank Electrode FL 

5550 

Top 

30 

110 

Pl / Me 

-- 

 

-- 

Tank Sensor FL 

5530 

Lateral Side/ 

Top 

30 

100 

Pl / Me 

-- 

 

 

 

Summary of Contents for Info Panel Pro

Page 1: ...tion place in the front panel of the furniture should be chosen in such a way that the contrast of the display be not hindered sun light The small mounting depth of only 12 mm of the electronic system allows flush mounting into commercial furniture boards to ensure that an optimum installation place can always be chosen without losing precious storage space The clear opening of the furniture cutou...

Page 2: ...penditure of force is required We therefore recommend to carefully using pliers for the first insertion Switch Functions Main Switch This switch is used to switch the entire power supply in the camper on or off It is indicated by the red light emitting diode Main Switch The switch is designed for small to medium sized systems which means that the maximum switching current of the board supply shoul...

Page 3: ...s 12 75 V If the brightness of the light emitting diodes is different the battery voltage tends to the light emitting diode being the brighter one The range of operation of the lead battery 12 V is indicated by the red and green light emitting diodes and it is valid for inferior to normal load current consumption of the battery Green means o k If powerful consumers with high current consumption ar...

Page 4: ...lay When pressing the key the instantaneous level of the tank will be displayed If they key is pressed again the display is switched off In case of an empty tank the lowest LED is always lighting dimly at least brightness 10 minutes after the last activity the display will be switched off automatically for reasons of power saving Activation of the tank transmitters is effected together with the di...

Page 5: ...cted to 1 Fused battery direct voltage with nominal voltage 12 V or 24 V 2 Technically faultless condition 3 Installation in a well ventilated room protected from rain humidity dust aggressive battery gas as well as in an environment being free from condensation water 4 With a rear insulating cover of the display unit Never use the unit at locations where the risk of gas or dust explosion exists C...

Page 6: ... 6 Connection Plan Info Panel Pro Rear View ...

Page 7: ...iguration of Connections Info Panel Pro Female Connector 6 3 mm yellow 6 3 mm yellow 6 3 mm blue Designation Board Battery Minus Body Ground Board Battery Plus Output Consumers of Board Battery Starter Storage Battery Plus Tank Pulse Fresh Water Tank Pulse Sewage Water Tank Pulse Feces Tank switched for Fresh Water Sewage Water and Feces Tank Pump Plus Battery Protector see Page 3 No 1 2 2a 3 4 Fr...

Page 8: ...0 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in the household waste The product is RoHS compliant It complies with the directive 2011 65 EU for Reduction of Hazardous Substances in electrical and electronic equipment Delivery Scope 1 Pc Info Panel Pro 2 Pcs Female Connectors 6 3 mm yellow for 4 mm 6 mm 1 Pc Female Connector 6 3 mm blue for 1 mm 2 ...

Reviews: