- 4 -
Tank Displays:
The tank level is represented in form of a clearly arranged luminous bar with 10 light-emitting diodes (each) in three colours
allowing that the tank level can be read conveniently at a glance. Display is effected continuously; intermediate values are
displayed in variable brightness.
During refuelling and defuelling of the tanks, the continuously raising or dropping display shows a direct image of the
instantaneous tank level.
The fresh water tank display warns in time of an empty water tank. Due to its accuracy it is a very good aid for tank filling.
Also the sewage water and the feces tank display facilitate immediate disposal, which is appreciated by environment-
conscious users.
Level measurement requires installation of a tank transmitter (measuring sensor) at each tank, which must be connected to
the Info Panel Pro via three cables or two cables (as well as ground/battery minus).
* no longer available
Note:
All measuring sensors listed in the table supply a continuous signal and are designed for continuous operation. Thus, their
design is optimally adapted to an operation at the Info Panel Pro.
Former measuring sensors, such as the Tank Transmitter Set, order No. 5510, and the Tank Probe, order No. 5520, work
according to the conductive measuring method (conductivity). Due to the 7-stage measurement, they are no longer suitable
for continuous operation at the tank displays S.
Operation of the Fresh Water Single Display:
When pressing the key, the instantaneous level of the tank will be displayed.
If they key is pressed again, the display is switched-off.
In case of an empty tank, the lowest LED is always lighting dimly at least brightness.
10 minutes after the last activity, the display will be switched-off automatically for reasons of power saving.
Activation of the tank transmitters is effected together with the display.
Operation of the Sewage Water / Feces Double Display:
When pressing the key, the instantaneous level of the sewage water tank will be displayed. The LED “Sewage
Water” is lighting.
If the key is actuated for a second time, it will be switched to the feces tank. The LED “Feces Tank” is lighting.
If they key is pressed for a third time, the display is switched-off **.
In case of an empty tank, the lowest LED is always lighting dimly at least brightness.
10 minutes after the last activity, the display will be switched-off automatically for reasons of power saving.
Activation of the tank transmitters is effected together with the display.
** “Feces Tank” will be completely skipped, if there is no tank transmitter connected!
Required Measuring Sensors (1 each Tank, for 12 V and 24 V)
Selection acc. to Tank volume, tank height and installation possibility at the tank:
Tank Transmitter,
Measuring Sensor
Type
Order
No.
Installation
at the Tank
Adjustable
Tank Height in
cm
min. max.
Tank Material
Pl = Plastic
Me = Metal
Tank Volume
Tank Electrode 25
5538
Top/Bottom
10
25
Pl / Me
--
Tank Electrode 35*
5540*
Top/Bottom
15
35
Pl / Me
--
Tank Electrode 50
5542
Top/Bottom
20
50
Pl / Me
--
Tank Electrode FL
5550
Top
30
110
Pl / Me
--
--
Tank Sensor FL
5530
Lateral Side/
Top
30
100
Pl / Me
--