Start-up:

 

 

Always disconnect the power supply to the battery prior to working on the electric system to avoid 
short-circuits!

 

 

The Info Panel Pro is connected prior to the final installation. Therefore, the length of the connection cable should be 
sufficient, in order to facilitate connection and installation of the display unit. It is, however, recommendable to use 
connection cables of different colours to avoid malfunctions due to mixed up connections. 
The connections of the panel are combined on the terminal strip, and they are marked on the on the board by numbers. 
The numbering of all VOTRONIC units has been assigned systematically to the corresponding connections, and they are 
explained by a label on the rear side. Thus, the configuration of connections is always available. 

 
It doesn't make any difference if the connections are plug-in type terminal screws or female connectors. 
It is 

IMPORTANT

 to carefully screwing down and crimping the stripped cable with all single wires, observing 

that no single wires jut out laterally!  

 

 
When inserting brand-new female connectors for the first time, expenditure of force is required. 

 

We therefore recommend to carefully using pliers for the first insertion.

 

 

 

 
 
 

Switch Functions: 

 

Main Switch: 

This switch is used to switch the entire power supply in the camper on or off. It is indicated by the red light-emitting diode 
“Main Switch”.    

The switch is designed for small to medium-sized systems, which means, that the maximum switching current of the board 
supply should not exceed approx. 16 A. 

In case of higher current load due to consumers, switching by a VOTRONIC Battery Protector is recommendable, see page 3, 
“Automatic Protection against Total Discharge and Remote-controlled Main Switch”. 

 
Operation:

 

If the main switch is actuated, all displays will be started for a short moment for reasons of testing, and all signal LEDs on 
the display will be lighting up. 

After that the unit will change to normal operation. The board battery, the fresh water and the sewage water tank will be 
displayed, and usual operation is allowed. 10 minutes after the last activity, the display will be switched-off automatically 
for reasons of power saving. 

 

 

 

Pump  (Pump Main Switch):

 

This switch is used to switch-on the pump of the water supply, which is indicated by the red LED “Pump". 

 

Any commercially available pump, the current consumption of which does not exceed approx. 10 A, can be connected. 
 

Summary of Contents for Info Panel Pro

Page 1: ...tion place in the front panel of the furniture should be chosen in such a way that the contrast of the display be not hindered sun light The small mounting depth of only 12 mm of the electronic system allows flush mounting into commercial furniture boards to ensure that an optimum installation place can always be chosen without losing precious storage space The clear opening of the furniture cutou...

Page 2: ...penditure of force is required We therefore recommend to carefully using pliers for the first insertion Switch Functions Main Switch This switch is used to switch the entire power supply in the camper on or off It is indicated by the red light emitting diode Main Switch The switch is designed for small to medium sized systems which means that the maximum switching current of the board supply shoul...

Page 3: ...s 12 75 V If the brightness of the light emitting diodes is different the battery voltage tends to the light emitting diode being the brighter one The range of operation of the lead battery 12 V is indicated by the red and green light emitting diodes and it is valid for inferior to normal load current consumption of the battery Green means o k If powerful consumers with high current consumption ar...

Page 4: ...lay When pressing the key the instantaneous level of the tank will be displayed If they key is pressed again the display is switched off In case of an empty tank the lowest LED is always lighting dimly at least brightness 10 minutes after the last activity the display will be switched off automatically for reasons of power saving Activation of the tank transmitters is effected together with the di...

Page 5: ...cted to 1 Fused battery direct voltage with nominal voltage 12 V or 24 V 2 Technically faultless condition 3 Installation in a well ventilated room protected from rain humidity dust aggressive battery gas as well as in an environment being free from condensation water 4 With a rear insulating cover of the display unit Never use the unit at locations where the risk of gas or dust explosion exists C...

Page 6: ... 6 Connection Plan Info Panel Pro Rear View ...

Page 7: ...iguration of Connections Info Panel Pro Female Connector 6 3 mm yellow 6 3 mm yellow 6 3 mm blue Designation Board Battery Minus Body Ground Board Battery Plus Output Consumers of Board Battery Starter Storage Battery Plus Tank Pulse Fresh Water Tank Pulse Sewage Water Tank Pulse Feces Tank switched for Fresh Water Sewage Water and Feces Tank Pump Plus Battery Protector see Page 3 No 1 2 2a 3 4 Fr...

Page 8: ...0 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in the household waste The product is RoHS compliant It complies with the directive 2011 65 EU for Reduction of Hazardous Substances in electrical and electronic equipment Delivery Scope 1 Pc Info Panel Pro 2 Pcs Female Connectors 6 3 mm yellow for 4 mm 6 mm 1 Pc Female Connector 6 3 mm blue for 1 mm 2 ...

Reviews: