background image

 

 
 
Installation and Operating Manual 

 

D+ Simulator 

No. 3066

 

 

The VOTRONIC D+ Simulator is applied for detection of the charging data in a 12 V board mains. 

Whenever it is required that additional consumers shall only be switched-on, if the dynamo supplies current and the motor 
is running, or if simultaneous supply of the board battery is required by interconnection of board and starter battery over a 
cutoff relay, the D+ contact of the dynamo will be used for determination of the charging mode of a dynamo. 

If the D+ contact is not accessible, or even not existing, as it is the case for later dynamos, the VOTRONIC D+ Simulator 
produces this signal by supervision of the starter battery, which is connected to the dynamo. 

 

Note:   This device is not suitable for use with Euro-6 vehicles.  The generator management system in 

Euro-6 vehicles does not allow the start battery voltage to be connected to a running or 
stopped motor. 

 

 

Please read this operating and installation manual thoroughly prior to connection and start-up. 

 
 

 
The VOTRONIC D-Simulator works automatically and maintenance-free and offers the following functions: 

 

Low own consumption

 

 

Display at D+ “ON” by LED 

 

Terminal (output):

 Possibility to connect a power relay with holding current of max. 1.0 A (+ switching, overload-

proof and short circuit-proof). 

 

Switching delay approx. 4 seconds, avoiding control errors in case of voltage drops 

 

With the tendency of oscillation, automatic prolongation of the cut-off delay up to 90 seconds 

 

The charging mode is recognized due to an intelligent voltage evaluation of the battery, which is connected to the dynamo. 
So, it is possible to energize a topped battery cut-off relay, to recharge the board battery with running motor. 

Further application possibilities are resulting for control of additional consumers, which shall only be activated, if the 
battery had been charged sufficiently. An example is the start of the air-conditioning system during driving or the activation 
of fans for interior ventilation.   

A continuously lighting LED (light-emitting diode) indicates that the control output had been activated. Thus, recharging of 
the starter battery can be supervised. Furthermore, the D+ Simulator can be used for remote charging control by simply 
connecting the terminal to a display (12 V lamp).    

 
 
 
Installation:

 

 

The VOTRONIC D+ Simulator can be operated at any location being protected from humidity. 

 

Any fitting position is possible. 

 

Install the upper housing prior to the final installation of the unit 

 

The cable feed is possible either at the lateral lower edge of the housing or at the housing bottom (invisible). 

Summary of Contents for D+ Simulator

Page 1: ...ct a power relay with holding current of max 1 0 A switching overload proof and short circuit proof Switching delay approx 4 seconds avoiding control errors in case of voltage drops With the tendency of oscillation automatic prolongation of the cut off delay up to 90 seconds The charging mode is recognized due to an intelligent voltage evaluation of the battery which is connected to the dynamo So ...

Page 2: ...eck 2 The terminal will be activated for a short moment test Function Activation Terminal If the battery voltage exceeds 13 7 V during charging the terminal will be activated after 4 seconds Deactivation If the battery voltage drops below 13 0 V after the end of the charging process the terminal will be deactivated after 4 seconds Oscillation Suppression If the battery voltage drops quickly and re...

Page 3: ...uit empty conduit Check live cables or leads periodically for insulation faults points of break or loosened connections Occurring defects must be remedied immediately The unit is to be disconnected from any connection prior to execution of electrically welding or work on the electric system If the non commercial end user is not able to recognize the characteristic values being valid for a unit or ...

Page 4: ...lation tendency 12 3 V always 4 seconds Connection Operating Voltage and Control Output 3 x Plug in Terminal Screw 1 mm Fitting Position of Unit any Working Temperature Range 20 45 C System of Protection IP21 Dimensions 55 x 36 x 17 mm Weight 30 g Ambient Conditions Humidity of Air max 95 RH no condensation Subject to misprints errors and technical modification without notice All rights reserved p...