Declaration of Conformity: 

In accordance with the provisions of Directives 2014/35/EU, 2014/30/EU, 2009/19/EC, this 
product complies with the following standards or normative documents: 
EN55014-1;  EN55022 B;  EN61000-6-1;  EN61000-4-2;  EN61000-4-3;  EN61000-4-4;   
EN62368-1;  EN50498.

 

 

The product 
must not be 
disposed of in 
the household 
waste. 

 

The product is RoHS compliant. 
It complies with the directive 
2011/65/EU for Reduction of 
Hazardous Substances in electrical 
and electronic equipment. 

 

 

 

 

 

 

 

Safety Regulations: 

 

Appropriate Application: 

The VOTRONIC D+ Simulator has been designed according to the valid safety regulations. 

  

Appropriate application is restricted to: 

1.

 

Installation of the indicated fuses near the battery to protect the cabling of the unit. Technically faultless 
condition. 

3.

 

Installation in a well-ventilated room, protected from rain, humidity, dust, aggressive battery gas, as well as 
in an environment being free from condensation water. 

 

Never use the unit at locations where the risk of gas or dust explosion exists! 

 

Open-air operation of the unit is not allowed.

 

 

Never lay 12 V (24 V) cables and 230 V mains supply cables into the same cable conduit (empty conduit).

 

 

Check live cables or leads periodically for insulation faults, points of break or loosened connections. Occurring 
defects must be remedied immediately.  

 

The unit is to be disconnected from any connection prior to execution of electrically welding or work on the 
electric system. 

 

If the non-commercial end-user is not able to recognize the characteristic values being valid for a unit or the 
regulations to be observed, a specialist is always to be consulted. 

 

The user/buyer is obliged to observe any construction and safety regulations. 

 

The unit is not equipped with parts, which can be replaced by the user. 

 

Keep children away from batteries and connections. 

 

Observe the safety regulations of the battery manufacturer. 

 

Ventilate the battery room. 

 

Non-observance may result in injury or material damage. 

 

The warranty period is 36 months from the purchase date (against presentation of the sales slip or invoice). 

 

The warranty will be void in case of any inappropriate utilisation of the unit, if it is used beyond the technical 
specification, in case of improper operation or external intervention. We do not assume any liability for any 
damage resulting hereof. The liability exclusion is extended to any service being executed by third, which has 
not been ordered by us in writing. Service is to be effected exclusively by VOTRONIC Lauterbach. 

Summary of Contents for D+ Simulator

Page 1: ...ct a power relay with holding current of max 1 0 A switching overload proof and short circuit proof Switching delay approx 4 seconds avoiding control errors in case of voltage drops With the tendency of oscillation automatic prolongation of the cut off delay up to 90 seconds The charging mode is recognized due to an intelligent voltage evaluation of the battery which is connected to the dynamo So ...

Page 2: ...eck 2 The terminal will be activated for a short moment test Function Activation Terminal If the battery voltage exceeds 13 7 V during charging the terminal will be activated after 4 seconds Deactivation If the battery voltage drops below 13 0 V after the end of the charging process the terminal will be deactivated after 4 seconds Oscillation Suppression If the battery voltage drops quickly and re...

Page 3: ...uit empty conduit Check live cables or leads periodically for insulation faults points of break or loosened connections Occurring defects must be remedied immediately The unit is to be disconnected from any connection prior to execution of electrically welding or work on the electric system If the non commercial end user is not able to recognize the characteristic values being valid for a unit or ...

Page 4: ...lation tendency 12 3 V always 4 seconds Connection Operating Voltage and Control Output 3 x Plug in Terminal Screw 1 mm Fitting Position of Unit any Working Temperature Range 20 45 C System of Protection IP21 Dimensions 55 x 36 x 17 mm Weight 30 g Ambient Conditions Humidity of Air max 95 RH no condensation Subject to misprints errors and technical modification without notice All rights reserved p...

Reviews: