- 2 -

 

 

 

Installation: 

 

 

Fasten the D+ Simulator to a suitable place on the engine using a clip. 

 

The function of the engine must not be impaired by the installation. 

 

The vehicle manufacturer’s specifications must be observed. 

 

Any installation location can be selected. 

 

Attach the clip on the bottom third (opposite the connection side) of the device. 

 

Check the device is mechanically secured! 

 

Lay cables so that they cannot touch any parts with temperatures over 100°C. 

 

Fasten cables without any tensile forces. 

 

Fasten cables so that they remain capable of moving on the sensor (mechanical stress). 

 

Connection: 

 

 

Wire the device according to connection diagram. 

 

 

 

 

Note: 

The device can be operated either on the starter battery, vehicle battery, Terminal 15 or switch outputs.  

The additional voltage detection may need deactivating, see corresponding chapter.  

 

 

Summary of Contents for D+ Simulator Pro

Page 1: ...and is therefore particularly suitable for vehicles that have an alternator management system which may be for example Euro 6 vehicles With its low power consumption of less than 3mA it meets the req...

Page 2: ...on side of the device Check the device is mechanically secured Lay cables so that they cannot touch any parts with temperatures over 100 C Fasten cables without any tensile forces Fasten cables so tha...

Page 3: ...or functions can be set with the trimmer Setting the switch off delay To set the required switch off delay set the trimmer to the corresponding position The switch off delay specifies how long the D...

Page 4: ...on and voltage After switching on the D signal the voltage may drop back below this threshold alternator management The D Simulator is then controlled purely by vibration again If the device is suppli...

Page 5: ...d it is not obvious to the non professional user which specific values apply to a device or which regulations must be complied with a specialist must be consulted The user buyer is responsible for com...

Page 6: ...3 A internal fuse self resetting Switch output switching threshold 13 65 13 85 V 27 3 27 7 V additional voltage detection Switching delay on 4 seconds Switching delay off 10 s 5 min adjustable Operati...

Page 7: ...o the following standards or normative documents EN55014 1 EN55022 B EN61000 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in household waste The produc...

Page 8: ...nical changes All rights reserved particularly with regard to reproduction Copyright VOTRONIC 11 2020 Made in Germany by VOTRONIC Elektronik Systeme GmbH Johann Friedrich Diehm Str 10 D 36341 Lauterba...

Reviews: