background image

- 6 -

 

 

 

 

 

 

 

Technical data:

 

D+ Simulator Pro 

 

System voltage DC: 

12 V / 24 V  (voltage range 10 - 32 V) 

Intrinsic current consumption at rest: 

< 0.003 A   

Intrinsic current consumption when output active: < 0.007 A 

 

 

Switch output: 

Positive potential, + switching, PNP output 

Max. power rating 

0.3 A, internal fuse, self-resetting 

 

Switch output switching threshold: 

13.65 … 13.85 V / 27.3 … 27.7 V 

(additional voltage detection) 

 

Switching delay on: 

4 seconds 

 

Switching delay off: 

10 s…5 min, adjustable 

 

   

Operating voltage and control output connection:  

 

3 x connection lead 0.75mm², 2 m long, permanently installed 

Device installation location:  

any  

Working temperature range: 

-40 … +105° C 

Protection class:   

IP64 

Dimensions (without connection leads):  43 x 25 mm, cylindrical 

Weight: 

 

100 g 

 

 

 

Summary of Contents for D+ Simulator Pro

Page 1: ...and is therefore particularly suitable for vehicles that have an alternator management system which may be for example Euro 6 vehicles With its low power consumption of less than 3mA it meets the req...

Page 2: ...on side of the device Check the device is mechanically secured Lay cables so that they cannot touch any parts with temperatures over 100 C Fasten cables without any tensile forces Fasten cables so tha...

Page 3: ...or functions can be set with the trimmer Setting the switch off delay To set the required switch off delay set the trimmer to the corresponding position The switch off delay specifies how long the D...

Page 4: ...on and voltage After switching on the D signal the voltage may drop back below this threshold alternator management The D Simulator is then controlled purely by vibration again If the device is suppli...

Page 5: ...d it is not obvious to the non professional user which specific values apply to a device or which regulations must be complied with a specialist must be consulted The user buyer is responsible for com...

Page 6: ...3 A internal fuse self resetting Switch output switching threshold 13 65 13 85 V 27 3 27 7 V additional voltage detection Switching delay on 4 seconds Switching delay off 10 s 5 min adjustable Operati...

Page 7: ...o the following standards or normative documents EN55014 1 EN55022 B EN61000 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in household waste The produc...

Page 8: ...nical changes All rights reserved particularly with regard to reproduction Copyright VOTRONIC 11 2020 Made in Germany by VOTRONIC Elektronik Systeme GmbH Johann Friedrich Diehm Str 10 D 36341 Lauterba...

Reviews: