, Page 16 of 22
Axle temperature
Time after sensor is adhesive bonded with Panacol GTH-T
+10 °C to +30 °C
(+50 °F to +86 °F)
T1
T2
T3
T4
15 min
30 min **
5 hours
24 hours
T1 - You can do first test of sensor. One or two persons can enter the vehicle.
T2 - Protection cover can be mounted. One hour later paint or corrosion spray can be added.
T3 - Vehicle can be driven for LO and HI calibration.****
T4 - Vehicle can be driven with normal load - recommandation.
** - Vehicle can be moved without any problems.
**** - We recommend vehicle to be unloaded after HI calibration until next day.
Table 1: Time after sensor(s) are adhesive bonded with Panacol GTH-T
Step 8
Prepare the adhesive and sealing compound for connecting
the sensor to the axle.
We recommend CARSYSTEM
®
UNIFLEX PU for best
performance.
Optional Teroson MS 9399 can be used (shown in Fig.
33 – 37).
Fig. 32: CARSYSTEM
®
UNIFLEX PU
Step 9
Carefully apply the adhesive and sealing compound
completely underneath the sensor to fill up the whole space
between the surface and the sensor.
Do not apply pressure to sensor.
Fig. 33: Applying the adhesive and sealing compound
underneath the sensor
!
!
!