37
Alarm
This option allows you to manage all possible alarm messages. Multiple errors must be managed one by one,
starting from the first one that occurred. In these situations, an intermittent "Alarm!" signal will be emitted on the
home screen. The intermittent messages "Alarm!", "Block!" and “OFF” will be displayed only in the event of a "No
Frost" alarm.
In all cases, you can switch on the ALARM menu to view the necessary actions and reset errors. The various
situations that generate alarm signals are described below.
Filters
When the preset time period has elapsed, a pre-alarm is displayed and a filter check/cleaning is required.
When the preset time period has elapsed, an alarm is displayed and filter replacement is required. The error and
counter can be reset after filter replacement (see "Maintenance and Cleaning").
NOTE: the counter can also be reset at any time by accessing the corresponding function in the Installer Menu.
ENGLISH
ALARM
REPLACE
FILTER.
RESET? YES
MAIN MENU
USE MENU
ALARM
SETUP
ALARM
CHECK OR
CLEAR
FILTER
MAIN MENU
USE MENU
ALARM
SETUP