background image

Description and operation

Vort HA is a dual-flow controlled mechanical ventilation system featuring the combination of normal ventilation
provided by outside air, using a heat recovery unit of the Vortice range, with antibacterial treatment of the air
flow extracted from the internal environment. The pairing of Vort HA and recovery unit is described here as the
"system", and the Vort HA stand-alone as the "appliance".  The internal environment of the building is referred
to generically as the "dwelling". 

The  system  comprises  two  elements:  a  heat  recovery  unit  of  the  Vortice  range,  and  a  filter  unit,  detached
physically from the heat recovery unit although the two are linked closely in terms of electronic control. Also
required  are  lengths  of  duct  (supplied  separately  as  accessories)  to  connect  the  two  components  one  with
another.

Fig.1  illustrates  the  operation  of  the  system  schematically:  the  flow  of  air  exhausted  to  the  outside  of  the
building is intercepted, directed through an antibacterial filter and finally returned to the dwelling. (Fig.1 - HA
MODE). 

These  appliances  have  been  designed  for  use  in  residential  and
commercial properties.

8

ENGLISH

 1

 1

MANDATA

ARIA VIZIATA

VERSO

L’ESTERNO

ASPIRAZIONE

ARIA FRESCA

DALL’

ESTERNO

ASPIRAZIONE

ARIA VIZIATA

DA

CASA

MANDATA

ARIA PULITA

IN

CASA

ASPIRAZIONE

ARIA FRESCA

DALL’

ESTERNO

ASPIRAZIONE

ARIA VIZIATA

DA

CASA

MANDATA

ARIA PULITA

IN

CASA

HR MODE

HA MODE

Summary of Contents for VORT HA

Page 1: ...el 39 02 90 69 91 Fax 39 02 90 64 625 ITALIA VORT HA COD 5 471 084 133 28 04 2015 VORTICE FRANCE 15 33 Rue Le Corbusier Europarc 94046 CRETEIL Cedex Tel 33 1 55 12 50 00 Fax 33 1 55 12 50 01 FRANCE VO...

Page 2: ...one e Pulizia 6 Informazione importante per lo smaltimento ambientalmente compatibile 6 Read the instructions contained in this booklet carefully before using the appliance Vortice cannot assume any r...

Page 3: ...ata fisicamente ma strettamente legata alla prima dal punto di vista della gestione elettronica A questi dispositivi si aggiungono i tratti di tubazione forniti separatamente come accessori necessari...

Page 4: ...stenza Tecnica autorizzato Vortice In caso di cattivo funzionamento e o guasto dell apparecchio rivolgersi subito ad un Centro Assistenza Tecnica autorizzato Vortice e richiedere per l eventuale ripar...

Page 5: ...imuovere il nastro che blocca le serrande interne N B Prima dell installazione rimuovere l imballo del filtro interno N B Il dispositivo deve essere montato con la scatola elettrica rivolta verso i tu...

Page 6: ...U Dall unit HRU nero black blu blue marrone brown RD L1 N1 BL N2 PLC HA Supply Supply TTL BK DI1 DI2 AO3 AO4 AO5 12V AI1 AI2 AI3 AI4 AI5 GND DO1 DO2 DO3 6 LAN BL RD BK 4 4 BL BR Y G CAVO PER CONNESSIO...

Page 7: ...indica che il prodotto alla fine della propria vita utile dovendo essere trattato separatamente dai rifiuti domestici deve essere conferito in un centro di raccolta differenziata per apparecchiature...

Page 8: ...ed physically from the heat recovery unit although the two are linked closely in terms of electronic control Also required are lengths of duct supplied separately as accessories to connect the two com...

Page 9: ...thout delay If the appliance does not function correctly or develops a fault contact a Vortice Technical Support Centre without delay Ensure that only original Vortice replacement parts are used for a...

Page 10: ...installation remove the packing from the internal filter N B The appliance must be positioned with the electrical enclosure facing the ducts routed to the outside of the building The appliance is des...

Page 11: ...unit HRU nero black blu blue marrone brown RD L1 N1 BL N2 PLC HA Supply Supply TTL BK DI1 DI2 AO3 AO4 AO5 12V AI1 AI2 AI3 AI4 AI5 GND DO1 DO2 DO3 6 LAN BL RD BK 4 4 BL BR Y G CAVO PER CONNESSIONE HA W...

Page 12: ...time To renew the HA filter proceed as follows see also figure 5 open the flap by turning the knob remove the filter by pulling downwards fit the new filter ensuring it is full inserted close the fla...

Page 13: ...ng and environmentally compatible disposal of waste equipment avoids unnecessary damage to the environment and possible related healthrisks and also promotes recycling of the materials used in the app...

Page 14: ...RVENTION TIMBRO CENTRO ASSISTENZA STAMP OF TECHNICAL ASSISTANCE CENTRE CACHET SERVICE APRES VENTE TAGLIANDO INTERVENTO IN GARANZIA CERTIFICATE OF WORK PERFORMED UNDER GUARANTEE COUPON INTERVENTION SOU...

Page 15: ...valida su tutto il territorio italiano Modalit e condizioni di attivazione della garanzia Gli interventi in garanzia riparazioni o sostituzioni del prodotto ovvero delle parti difettose saranno esegu...

Page 16: ...NTIE DA CONSERVARE TO BE RETAINED A CONSERVER Esclusioni La presente garanzia non copre Le rotture provocate dal trasporto I difetti o guasti derivanti da uso non corretto o improprio da parte del cli...

Reviews: