ENGLISH
16
Description and operation
The product you have purchased is an industrial helical fan.
The appliance is designed for installation in potentially explosive atmospheres, according to the technical
specifications stated in the table below:
ATEX MOTOR CLASSIFICATION
II
Motors for surface systems (other than mining)
2
Category 2: high protection level
G
A
S
G
Explosive atmosphere due to presence of flammable gas vapours or mists
Ex e
Enhanced safety
II
Gas group
T4
Temperature class 135°C
IP54
Minimum protection rating for ‘Ex e’ and ‘Ex nA’
P
O
W
D
E
R
D
Explosive atmosphere due to presence of combustible powder
Ex tD A21
Housings tD method A suitable for zone 21 (cat. 2D)
IP65
IP protection rating for conductive powders (at least IP6X)
ATEX FAN CLASSIFICATION
CE
Mark of conformity with European directives
Specific mark regarding protection against explosions
EN 14986
Design Standard for fans operating in potentially
explosive atmospheres
II 2G b T4 X
II 2D b T135 X
For electrical safety, see also
ATEX MOTOR CLASSIFICATION
Summary of Contents for E 254M ATE
Page 166: ... تادعملاو يتلا مت ؤارش á ا á ي فئافل ةحورم ةيعانصلا 166 ...
Page 168: ...5 1 14 6 A 168 12 ...
Page 169: ...169 يروحملا حوارملا ةيعانصلا ...
Page 170: ...170 ...
Page 171: ... 171 ...
Page 174: ... 174 ...
Page 175: ...20 15 175 13 18 13 18 ...
Page 177: ...4 4 6 6 7 7 5 5 5 8 8 9 9 177 ...
Page 178: ...10 10 11 12 12 16 13 13 14 14 15 15 16 16 178 ...
Page 179: ...17 17 179 18 18 ...