Special caution for heating function. (Only for models 11HP, 13 HP)
1. Install the exhaust pipe well, in order to exhaust the cool air to outdoor. (Please refer to the instruction ma-
nual for installation method.)
2. Fix the drainage to be continuous drainage (i.e. drain the water by water tube).
3. Working range for heating function is 7°C to 25
o
C .
Special caution for cooling function
Woking range for cooling function is from 18°C to 35
o
C.
For temperature outside this range, the unit may not work properly.
PROBLEMS CHECK LIST
The air conditioner does not run
- Is the air conditioner plugged in?
- Is there a power failure ?
- Is the “full water” indicator flashing?
- Is the room temperature below the set temperature?
The machine seems to do little
- Is there direct sunshine ? (please avoid direct sunshine in the
room or on the appliance)
- Are there windows or doors open?
- Are there too many people in the room?
- Is there something in the room producing lots of heat?
Too noisy
- Is the machine positioned unevenly so as to create vibration?
- Is the floor underneath the machine uneven?
The compressor doesn’t run
- Is so, it is possible to overheat protection of the compresso is on.
just wait for the temperature to drop.
Maintenance and Cleaning
Always unplug the air conditioner form the mains supply before cleaning and/or repairing.
To maximize the efficiency of the air conditioner, clean the unit regularly.
Extraordinary maintenance operations or repairs must be done by professional qualified staff. Call a VORTICE
Service Center.
Before doing maintenance operations , please check the followings :
- The capacitor must be discharged : this hall be done in a safe manner to avoid possibility of sparking;
- That no live electrical components and wiring are xposed while charging, recovering or purging the system;
- that there is continuity of earth bonding.
When breaking into the refrigerant circuit containing flammable refrigerants to make repairs, it is important to
follow the procedure listed below:
- Remove refrigerant;
- Purge the circuit with inert gas ;
- Evacuate;
- Purge the circuit with inert gas;
- Open the circuit by cutting or brazing.
Cleaning the housing
Use a soft, damp cloth to wipe the body clean.
Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions.
These all could possibly hurt the cabinet.