3. The compressor is selected according to the indoor temperature and the set temperature to achieve cooling
operation.
• when room temperature
≥
preset tempe1°C, the compressor is on, and the corresponding
indicator “COMP” “11” lights up.
• when room temperature
≤
preset temperature -1°C, the compressor shuts down and the corresponding
indicator "COMP." “11” is off.
• Set temperature = Indoor temperature, the compressor keeps the original state.
4. Anti-frost function is active in Cooling mode
SLEEP function
1. In cooling mode, by pressing the SLEEP button (E), the set temperature will increase 1°C at the 1st hour,
another 1°C at the second hour, then keeps at that temperature.
2. In heat mode(only in 11HP, 13HP models), by pressing the SLEEP button, the set temperature will descend
1°C at the 1st hour, another 1°C at the second hour, then keeps at that temperature.
3. In sleep mode, the ventilation will keep at low speed. Re-press the SLEEP button (E), the setting temperature
and ventilation speed will return to the pre-selected one.
4. The unit will shut down automatically after the SLEEP function running for 12 hours.
NOTE 1: Please note, the sleep function is not available while the machine is working in ventilation,
dehumidification, TiO2 and auto mode. It is only available in Cooling or Heating mode.(11HP, 13 HP).
NOTE 2: When the machine is in Sleep function, the fan speed will automatically set to low..
Fan only mode
1. The temperature is not adjustable in the Fan only mode, and the "FAN" indicator ‘7’ lights up;
2. high, medium and low speed can be selected, the corresponding indicator light is on.
Dehumidify (DRY) mode
1. In dehumidify (DRY) mode, the temperature cannot be adjusted, the ventilation will be fixed at low speed and
“DRY” indicator ‘8’ lights up. When the unit is operating in this mode, humidity extracted from the air is collected
in an internal tank. If the tank reaches full, the compressor and motor cut out automatically. At the same time,
the “Water Full” indicator ‘10’ comes on. An alarm will also sound. When the tank is full, drain the water as
shown in the page concerning “DRAINAGE”. You may also use the unit without having to empty the tank so
often by using “continuous drainage”, please also refer to the page about “DRAINAGE”.
2. Anti-frost function is active in deumidify mode.
3.When the room temperature is
≤
15°C, the compressor stops, when the temperature is
≥
17°C the
dehumidification operation starts again.
Heating function (11 HP, 13 HP models)
1. Thanks to the presence of the heat pump the air in the room can be heated. The LED “HEAT” “9” is on.
The Exhaust Pipe must be still fitted to allow the cold air to be removed in this mode & used in the usual way.
Also please fix the drainage to be continuous drainage (i.e. drain the water by water tube), because the condensed
water will be collected quickly. Under this system, the machine can run at HIGH, MEDIUM or LOW speed.
2. Fan speed (high, medium and low) can be selected and the corresponding function LED indicator is on.
3. The compressor is selected according to the indoor temperature and the set temperature to perform heating
operation:
• when room temperature
≥
preset tempe1°C, the compressor is on, and the corresponding LED
“COMP” “11” lights up.
• when room temperature
≤
preset temperature -1°C, the compressor shuts down and the corresponding
LED "COMP." “11” is off.
• Set temperature = Indoor temperature, the compressor keeps the original state.
“TiO2 function (only for the model with TiO2 function)
The TiO2 function (with photocatalysis) can block the spread of bacteria and viruses. This function is for air
quality improvement. To activate it, please press button TiO2. To turn off, press TiO2 button again.”