ELECTRICAL WORK
WARNING! An electric shock can be fatal. High danger due to a grid voltage and
voltage from the turbine that is operational.
➢
Ensure that the turbine is not operational before carrying out any connection
work.
➢
Only an authorized electrician is permitted to connect this equipment.
SETUR-M turbine generates a 3-phase alternating current (AC) which is then rectified to direct current
(DC), then inverted into a pure sine wave single-phase 220-240 V (110-120 V USA model) alternating
current (AC).
➢
Never disconnect the power connections of the generator while the equipment is energized.
➢
Wait at least five minutes before touching any components which are normally live.
➢
After switching off the generator, do not touch it until it has cooled down to ambient temperature.
The turbine is equipped with a waterproof power connector located on the
generator enclosure. It consists of a) bulkhead connector attached to the generator
enclosure and wired to the generator; b) cable connector with around 60 cm of
cable.
a) Extend the power cable to achieve the desired length. Hermetically insulate.
Wire 1- Black
Wire 2 - White
Wire 3 - Red
Wire 4 - Green
b) Connect the part of the connector with cable to a bulkhead part attached to the turbine.
c) Connect the power cable and a 3-phase bridge rectifier, which has to be installed by a certified
electrician in accordance with national and local codes, rules and regulations.
d) Connect the rectifier and the inverter. The installer must follow all the instructions outlined in the
Inverter's User's Manual.
Vortex Hydrokinetics LLC © 2019
SETUR-M User's Manual - Rev. 2M-A
Page 14 of 24