background image

16

English

6.

 Replace with genuine Vornado Filters.  Place the Filters in the unit 

and gently press around the perimeter of the Filter to ensure se-
cure placement.  

Note: Remove and discard the Filters you wish to replace.  The Ad-
vanced Carbon Filter must be placed in the unit before the HEPA 
Filter.  See PRODUCT INFORMATION for a detailed illustration.

5.

 To remove the Advanced Carbon Filter, after the Permanent Pre-

Filter and HEPA Filter have been removed, take hold of tab along 
the perimeter of Filter and pull to release.

Summary of Contents for PCO375DC

Page 1: ......

Page 2: ...EE Plus économe en énergie Más eficiencia energética MORE ENERGY EFFICIENT 80 UP TO LESS ENERGY Le contrôle précis de la vitesse Control preciso de velocidad PRECISE SPEED CONTROL SILENT POWER F U L Indicateur de la Qualité de l air Indicador de Calidad de Aire AIR QUALITY INDICATOR ...

Page 3: ...ir Quality Indicator 6 True HEPA Filtration 7 Control Panel 8 How to Use 9 User Tips 11 Filter Replacement 12 Silverscreen Tray and UV Bulb Replacement 17 Cleaning and Maintenance 19 Troubleshooting 20 CONTENTS MODELS PCO375DC PCO575DC OWNER S GUIDE PCO575DC PCO375DC ...

Page 4: ...er high temperature heat sources Do not use this product in a window on an uneven or unstable surface or near water The appliance power supply power cord and plug cannot come into contact with water Do not use this product on wet surfaces Do not use this product in a bathtub or shower or position product where it may fall into a bathtub laundry swimming pool or other water container Do not use thi...

Page 5: ...ning Refer to the CLEANING instructions provided Do not open appliance housing while product is plugged in To avoid risk of shock all service and or repairs must be done by a Vornado Authorized Service Center Skin or eye damage may result from directly viewing the light produced by the lamp in this apparatus Always disconnect power before relamping or servicing Replace Lamp With Lamp Model No UVC ...

Page 6: ... The packaging protects the appliance from transport damage The packaging materials are selected from the point of view of their environmental friendliness and disposal technology and are therefor recyclable Dispose of all packaging materials in an environmentally responsible manner SAVE THESE INSTRUCTIONS ...

Page 7: ...rs SILVERSCREEN TRAYS Reacts with UV light to break down harmful viruses bacteria and gases that HEPA and Carbon cannot capture UV BULB Emits UV light to activate the titanium dioxide coating on screen to break down harmful viruses bacteria and gases that HEPA and Carbon cannot capture TOUCH SENSITIVE CONTROL PANEL LED display and touch sensitive controls for easy and intuitive operation POWER COR...

Page 8: ... equipped to give you visual feedback of the air quality in your room The color bar displays the air quality in real time making your once invisible concerns visible VISUAL AIR QUALITY INDICATOR GREEN Good Air Quality ORANGE Moderate Air Quality RED Poor Air Quality ...

Page 9: ...t MD1 0023 Part MD1 0026 A convenient and hassle free way to recieve regular shipments of Vornado Filters direct to your door Eliminate the hassle of remembering to reorder Maintain the high efficiency of your Vornado Purifier by regularly replacing used Filters with fresh new ones How it works You select a plan and Vornado will send replacement Filters at the recommended maintenance interval To s...

Page 10: ...nglish CONTROL PANEL POWER HEPA FILTER REPLACEMENT SILVERSCREEN REPLACEMENT DOOR AJAR ADVANCED CARBON FILTER REPLACEMENT UV BULB REPLACEMENT CONTROL LOCK SLEEP MODE AUTO MODE AIRFLOW ADJUSTMENT QUICK CLEAN ...

Page 11: ...ease in airflow that will allow the unit to provide maximum air filtration Please note once Quick Clean mode is off the unit will return to the speed or mode it was in before activating Quick Clean AUTO MODE The PCO375DC 575DC will continuously monitor the air quality of the room to detect the presence of particles and gases odors In Auto Mode the fan speed will adjust as needed to maintain optimu...

Page 12: ...quipped with an indicator light to show when it is recommended to change the HEPA filter Refer to FILTER REPLACEMENT for instructions This feature is controlled by time of use The light will illuminate after 9 000 hours of run time has accumulated UV BULB REPLACEMENT Equipped with an indicator light to show when it is recommended to change the UV Bulb Refer to SILVERSCREEN TRAY AND UV BULB REPLACE...

Page 13: ...to prevent unit from being activated DOOR AJAR Indicator light shows when Front Panel is not securely closed Refer to FILTER REPLACEMENT on page 11 on how to properly replace door Note For optimum airflow air outlet should be unobstructed Ensure curtains and other items are far enough away from the unit to not be pulled into the side inlets or interfere with airflow 1 Keep retail carton to store u...

Page 14: ...nado Air Purifier is calibrated to achieve a 99 97 capture rate of particles 0 3 microns or larger only when used with Vornado Filters Note The bottom of the Front Panel B is held in place by magnets you will need to pull the Front Panel hard enough to overcome the resistance of the magnets Note The Front Panel is held in place by magnets you will need to lift the Front Panel hard enough to over c...

Page 15: ...e Filter has been removed take hold of the tab along the perimeter of Filter and pull to release 3 Remove the Permanent Pre Filter by pulling on the center tabs C You may need to flex the Permanent Pre Filter slightly to release the tabs at the top and bottom C C ...

Page 16: ...nt Note Remove and discard the Filters you wish to replace The Ad vanced Carbon Filter must be placed in the unit before the HEPA Filter See PRODUCT INFORMATION for a detailed illustration 5 To remove the Advanced Carbon Filter after the Permanent Pre Filter and HEPA Filter have been removed take hold of tab along the perimeter of Filter and pull to release ...

Page 17: ...ction the unit is designed to operate only if the Front Panel is in place Do not attempt to override this safety feature If after the Front Panel has been reinstalled the unit does not operate remove and reinstall the Front Panel to assure proper placement 7 Replace the Permanent Pre Filter by securing the bottom 2 tabs into bottom slots D Slightly flex the Permanent Pre Filter to se cure the top ...

Page 18: ...EPLACE HEPA REPLACE SCREEN REPLACE UV BULB depending on which item was replaced for at least 3 seconds The light will turn off confirming the indicator is reset Note Do not operate the Air Purifier without Vornado Advanced Carbon Filter and Vornado HEPA Filter in place Press for 3 seconds ...

Page 19: ...the tabs A while simultaneously pulling the door open 3 Remove the silverscreen Trays or UV Bulb Tray by pulling on the Tray handle Discard any used Trays WARNING Skin or eye damage may result from directly viewing the UV bulb in this unit Always disconnect power before replacing UV bulb A A UV BULB TRAY SILVERSCREEN TRAYS SILVERSCREEN TRAY AND UV BULB REPLACEMENT ...

Page 20: ...lb Tray or sliverscreen Trays Push the Tray into unit until it securely snaps into place Note All Trays fit into unit with ease and should not be forced into unit 5 Replace the Tray door by pushing door back over Trays until tabs securely snap into place ...

Page 21: ...Filters are changed Figure 2 4 The Permanent Pre Filter can be cleaned with a vacuum or rinsed Note If vacuuming use the vacuum brush attachment If rinsing allow Permanent Pre Filter to completely dry Note The motor is permanently lubricated so it needs no service No other serviceable parts other than Filters are contained within the unit STORAGE Follow the steps listed below when you are ready to...

Page 22: ...ILTER REPLACEMENT on page 18 Unit set to a low speed setting Adjust to a higher speed setting Debris build up on filter Check and replace Filters Airflow is blocked Remove obstruction There may be too much light in the room Either manually turn the unit to low speed for minimal sound or darken the room Sleep Mode may be selected When in low light or no light the unit will only operate at low speed...

Page 23: ... when pressing the Control Panel The Control Panel may not recognize quick taps or partial contact Check to ensure the UV Bulb Tray is properly installed Remove Tray and re insert Tray into unit Replace with a new UV Bulb If UV Bulb does not illuminate after proper installation or new UV Bulb replacement contact Consumer Service for assistance Control Panel is not re sponding UV Bulb is not illumi...

Page 24: ...by anyone other than Vornado damages which occur in shipment or are attributed to acts of God Improper product use which includes using an external device that alters or converts the voltage or frequency of electricity or shipping a Vornado product to a country not intended for use will void all warranties Any unauthorized product modification repair by unauthorized repair center or use of non app...

Page 25: ...ient parfaits Si celui ci ne l est pas nous corrigerons la situation we expect this product to be PERFECT vornado com 800 234 0604 help vornado com if it s not WE will make it right Esperamos que este producto sea perfecto Si no lo es ayúdenos a corregirlo ...