13
English
GRILLE & BLADE REMOVAL
Screwdriver required.
REMOVABLE GRILLE
1.
Using a phillips head screwdriver, remove grille by unscrewing the
4 screws located along the perimeter of the inlet grille at roughly
2, 5, 7, and 10 o’clock positions. This will release the grille. To
reattach, position grille so the logo in the center of the grille is
straight. Align the Locator Pin to reconnect grille. Once aligned
replace screws.
2.
Dust or wash with a mild dishwashing soap. Do not place grille in
the dishwasher. The excessive heat can distort the plastic.
BLADE REMOVAL
1.
It is possible to remove the blade should something accidentally
get wrapped around the motor shaft. First, remove the nut from
the shaft. Turn the nut
clockwise
to loosen. Pull the blade straight
out from the shaft. When replacing, the blade can only go on the
shaft one way. Be certain the flat side of the shaft aligns directly
with the corresponding flat side on the blade’s socket. Push the
blade all the way on the shaft until it bottoms out. Do not use a
hammer as this could result in bearing damage. Reinstall nut.
2.
Wipe blade with a damp cloth. If your Air Circulator is used in a
greasy environment, such as a kitchen, mild soap or a common
household cleaner may be necessary. Do not use solvents.
WARNING: To reduce the risk of electrical shock and injury to persons, unplug the circulator before removing grille or blade.
Screw
Screw
Screw
Screw
Locator Pin