background image

USING REPAIR

This mode is for LEAD-ACID batteries only. It is an advanced battery recovery mode for 
repairing old, idle, stratified or sulphated batteries. 

NOT all batteries can be recovered. For optimal results, take the battery through a full 
charge cycle, bringing the battery to full charge, before using this mode. 

When this mode is chosen, ensure you press Mode button for choosing appropriate 12V 
Mode(s) . 

One REPAIR cycle can take up to eight hours to complete the recovery process and will 
enter to charge (8 steps charging cycle) when completed. This mode uses a high charging 
voltage and may cause some water loss in WET (flooded) cell batteries. Plus, some 
batteries and electronics may be sensitive to high charging voltages. To minimize risks, 
disconnect the battery from the vehicle before using this mode.

STEP 1:

 DIAGNOSIS (Check if battery has connected with the charger and also check 

battery voltage)

STEP 2:

 DESULPHATION (If battery voltage is too low, programs automatically generate 

pulsing current to remove sulphate, up to 5 hours)

STEP 3:

 ANALYSE (Check if the battery voltage reaches to the threshold after 

desulphation, and charging begins if the battery voltage is OK)

STEP 4:

 SOFT START (Charge with echelon constant current)

STEP 5: 

BULK (Charge with constant maximum current until battery voltage is reached to 

the threshold)

STEP 6:

 ABSORPTION (Provide gradually declining current charge for maximum battery 

voltage)

STEP 7:

 ANALYSE (Test if the battery can hold charge)

STEP 8: 

MAINTENANCE (Continuously monitor the battery, and charging current will 

intelligently adapt to the variable battery voltage).

BATTERY LEVEL INDICATOR

CHARGING TIMES

LED

EXPLANATION

)

6V Light

Charging 

Charged

“6V LED” Solid” : only 6V mode desulfurization;“6V LED” 
+“CHARGING”Solid” 6V mode to the end of the normal charge;

“6V LED” +“CHARGING”Solid OFF+“CHARGED”Solid”6V mode 
charging is completed and MAINTENANCE.

12V

Charging 

Charged

“12V LED” Solid”only 12V mode desulfurization;
“12V LED” +“CHARGING”Solid”12V mode to the end of the normal 
charge;

“12V LED” +“CHARGING”Solid OFF+“CHARGED”Solid” 12V mode 

charging is completed.

24V Light

Charging

Charged

“24V LED ”Solid”only 24V mode desulfurization; “24V LED” 
+“CHARGING”Solid” 24V mode to the end of the normal charge;

“24V LED” +“CHARGING”Solid OFF+“CHARGED”Solid” 24V mode 

charging is completed and MAINTENANCE.

Battery 

Size (Ah)

Approx Time to Charge 

in Hours (12V)

Approx Time to Charge 

in Hours (24V)

50

3H @ 14.5V 

4H @ 14.8V

4H @ 29.6V

6H @ 30.4V

75

5H @ 14.5V

6H @ 14.7V

6H @ 29.5V

10H @ 31.1V

100

7H @ 14.5V

9H @ 15V

8H @ 29.1V

15H @ 31.2V

150

10H @ 14.5V 12H @ 14.8V 10H @ 29.5V

18H @ 30V

200

13H @ 14.5V

16H @ 15V

18H @ 29.5V

22H @ 31V

Different battery capacity and residual voltage would affect the charging time. Following data is only 

for reference (when discharge 12V lead-acid battery to 9V, with 5A discharge current; when discharge 

24V lead-acid battery to 18V, with 10A discharge current).

Summary of Contents for 3500083

Page 1: ...y burst and cause injury to persons and property WARNING NEVER charge a frozen damaged leaking or non rechargeable battery If battery electrolyte contacts skin or clothing wash immediately with soap a...

Page 2: ...LED it will automatically switches from full charge to maintenance status to maintain batteries during prolonged periods of storage without overcharging or damaging the battery The 3 5A Battery Charge...

Page 3: ...a positive grounded vehicle connect the BLACK NEGATIVE cable clamp first to the negative post of the battery then connect the RED POSITIVE cable clamp to the vehicle s chassis Do not connect the red...

Page 4: ...y systems may require an additional JUMP CHARGE CAUTION Do not use jump charge more than two times within a 24 hour period If two 2 jump charges cannot successfully start your vehicle have your batter...

Page 5: ...shold STEP 6 ABSORPTION Provide gradually declining current charge for maximum battery voltage STEP 7 ANALYSE Test if the battery can hold charge STEP 8 MAINTENANCE Continuously monitor the battery an...

Page 6: ...de will automatically shut down for 30 seconds as protec tion Disconnect the external device No LIGHT CAUSE SOLUTION 8 Corresponding charging mode LED quick flashing Battery cannot store electric char...

Page 7: ...The warranty only applies if the product is used solely in the manner indicated in the Warnings page of this and all other instructions have been followed accurately Any abuse of the product or the m...

Page 8: ...Thank you for purchasing the 15A Battery Charger VonHaus is a registered trademark of DOMU Brands Ltd Made in China for DOMU Brands Ltd M24 2RW...

Reviews: