VonHaus 2500446 Instructions Manual Download Page 4

A5P | 01

CONTROL PANEL 

POWER: 

When the unit is powered on the indicators and LED will display for 1 second after a ‘‘buzz’’ is heard the 

power indicator will be in standby mode. 

Pressing the Power Button will start the unit in default mode the fan will start and the display will indicate the 

current room humidity and also colour corresponding .

BLUE

 Ambient Humidity is below 45%

GREEN

 = Ambient Humidity is between 45% - 65%

RED = Ambient Humidity is above 65%

If an Error code is displayed please refer to the table in the back of this manual.

Pressing the power button again will power the unit off. 

MODE: Press this to cycle through Auto Mode / Continuous Mode / Sleep Mode

AUTO MODE: Both Fan speed and Humidity can be adjusted in this mode.

When the room humidity is higher than the selected humidity the fan and compressor will begin to operate after 3 

seconds. 

When the room humidity is below the set humidity the compressor and the fan will stop operating after a short 

delay.       

CONTINUOUS MODE: The humidity is not adjustable in this mode. The unit will run continuously.

SLEEPING MODE: In this mode you can adjust the humidity only. 

Press the button and after 10 seconds the indicators will turn dark and the fan speed will be set to low. 

To cancel sleep mode press the mode button again

NOTE: In sleep mode no error codes will be displayed and the fan speed is not adjustable. 

Humidity (HUM): This can be adjusted in Aromatic and sleep mode. Pressing the button will increase the set 

humidity by 5% increments, the unit will only cycle up through numbers.

To check the current room temperature press and hold the button and the display will show for 5 seconds.

TIMER BUTTON: The timer can be set 

for up to 24hrs.

Pressing the timer button will increase the timer by 1hr which will be shown on the display.

The timer when set will operate until time has elapsed and the unit will go into standby mode. 

To turn the timer off press the Timer Button until “00” is displayed. 

FAN SPEED: This can only be changed in Automatic mode. Pressing this will cycle the fan speed between High 

and Low.

LOCK: Press and hold this button and it will lock all button of from operation. To unlock press the button again, if 

the unit is turned off the child lock will be deactivated.  

Summary of Contents for 2500446

Page 1: ...ren Children should be supervised to ensure that they do not play with the appliance If the appliance is not functioning properly has been dropped damaged left outdoors or immersed in liquid do not use contact DOMU Brands Customer Services Do not use the appliance if any parts appear to be faulty missing or damaged Ensure all parts are securely attached before using the appliance CABLES AND PLUGS ...

Page 2: ...essment authority which authorises their competence to handle refrigerants safely in a accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refr...

Page 3: ...A5P 01 COMPONENTS 1 Control Panel 2 3 Colour Digital Display 3 Carry Handle 4 Air outlet 5 Air Inlet with Filter 6 Water Tank 7 Continuous Drainage hole 8 Overflow Pipe 9 Power Supply 1 2 3 8 5 6 4 9 7 ...

Page 4: ... this mode The unit will run continuously SLEEPING MODE In this mode you can adjust the humidity only Press the button and after 10 seconds the indicators will turn dark and the fan speed will be set to low To cancel sleep mode press the mode button again NOTE In sleep mode no error codes will be displayed and the fan speed is not adjustable Humidity HUM This can be adjusted in Aromatic and sleep ...

Page 5: ... not force the castor wheels to move over carpet or attempt to move the unit when it is in operation this may cause the tank to tip over and water to spill causing a hazardous environment 30cm 30cm Button Lock is active Tank Full Indicator Humidity Current Humidity Fan is on Low Fan is on High On Off indicator Sleep Mode Continuous Mode is active Automatic Mode Timer is set ...

Page 6: ...ipe Return the Tank into position for the unit to work and locate the pipe in a suitable place OVERFLOW PIPE WATER TANK WATER DISPOSAL When the Water Tank is full the Indicator will display and the unit will stop automatically Unplug from the mains and remove the tank by holding the grips either side and pulling away NOTE Do not set the tank down as the base is uneven Empty the tank and reinsert i...

Page 7: ...t bristle brush then with clean running water do not use any detergents or abrasive chemicals rinse the filter thoroughly and leave to completely dry for 24 hours CAUTION Do not operate the unit without the fil ter in place and ensure it is completely dry before re installing ...

Page 8: ...e ventilation machinery and outlets are operating adequately and are not obstructed 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and components inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If the fault cannot...

Page 9: ...ed out prior to leaving the site 16 Decommissioning Before carrying out this procedure it is essential that technician is completely familiar with the equipment and all its detail It is recommended good practice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to reuse of reclaimed refrige...

Page 10: ...the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppliers Only electric heating to the compressor body shall be employed to accelerate this process When oil is drained from a system it shall be carried out safely 19 Transport of equipment containing flammable refrigerants Determined by local regulations 20 Discarded appliances supplies flammable r...

Page 11: ...Customer Service for assistance No water is being collected The Unit is set to a lower level than the humidity in the room Temperature too low for water extraction Increase the temperature of the room Check the Unit for blockages Ensure the Unit is not too close to walls or furniture The unit stops regularly The Unit is defrosting allow the Unit to automatically defrost Increase the temperature of...

Page 12: ...ich it is used will invalidate the warranty Returned goods will not be ac cepted unless re packaged in its original packaging and accompanied by a relevant and completed returns form This does not affect your statutory rights No rights are given under this warranty to a person acquiring the appliance second hand or for commercial or communal use COPYRIGHT All material in this instruction manual ar...

Reviews: