background image

5/8” Maximum

latch bolt

projection

Figure 9

Top view;

faceplate not

shown for clarity

1/32”

Strike

lip

Door

Figure 10

Backbox

Faceplate

screws (2)

Backbox

screws (2)

Adjust Strike Lip

Remove two Phillips head

faceplate screws and remove

faceplate.
Loosen two Hex head

backbox screws and

move backbox

sideways as necessary,

then secure screws.

Replace faceplate

and secure faceplate

screws.

A

B

C

Page 3 of 4

11.

Install strike with two #12-24 mounting screws. Make sure clearance between latch bolt and strike lip is 1/32” (Figure 9).

If not, remove strike, adjust (Figure 10), and reinstall.

10.

If frame does not have built in mounting tabs, install mounting tabs supplied with strike as shown below (Figure 8).

Attach mounting tabs to

strike with two #12-24

screws and mark 4

mounting tab holes on

frame as shown below.

A

B

Drill four

mounting holes.

C

Mount the two

mounting tabs inside

frame using #10-24

screws as shown below.

D

Shim strike in or out as

needed until faceplate is

flush with frame.

Frame too thick

Add shim(s)

between tabs

and strike

Frame too thin

Add shim(s)

between tabs

and frame

Shim

Shim

Figure 8

Mounting

tabs

1/4” thru hole

countersunk for

#10-24 flat head

screw, 4 places

12.

Test door: With strike unlocked, door opens with latch bolt extended. When door closes, latch bolt rides over strike lip

and relatches.

Shim

Mounting

tab

Mounting

tab

Flush

Flush

Summary of Contents for 5100

Page 1: ...fail secure FSE strike cannot be moved when strike is not powered If necessary remove backbox cover Figure 2 and changestrikemode by repositioning actuator Figure 3 1 For lock preparation see lock instructions 2 Install correct faceplate onto strike Figure 1 Figure1 Wiring must stay in slot 4 7 8 StandardANSI RoundCorner 10 24 flat head nylocscrews When using the electric strike in fail secure mod...

Page 2: ...or 24 AC DC convertor kit shown below is recommended 12 VDC Strike Wiring 24 VDC Strike Wiring 5 Check power source voltage 12 or 24 VAC or VDC 6 When using 12 VAC or 24 VAC power install SO kit to convert AC power to DC Figure 4 7 Wire strike solenoid for proper voltage Figure 5 Caution Donotconnect24VDCto12VDCconfiguredstrike 8 Test strike Apply solenoid power Fail secure FSE lip unlocks Fail sa...

Page 3: ...f frame does not have built in mounting tabs install mounting tabs supplied with strike as shown below Figure 8 Attach mounting tabs to strike with two 12 24 screws and mark 4 mounting tab holes on frame as shown below A B Drill four mounting holes C Mount the two mounting tabs inside frame using 10 24 screws as shown below D Shim strike in or out as needed until faceplate is flush with frame Fram...

Page 4: ...Cut out LongFaceplateSuggestedCut out L C lock and strike 31 32 4 1 8 4 7 8 5 8 2 7 16 1 1 4 2 1 16 C strike L 1 1 2 1 11 16 5 32 radius on 4 corners Aluminum frame 1 11 16 3 3 8 3 32 1 1 16 1 31 32 7 15 16 23 32 3 31 32 1 7 16 5 32 radius on 4 corners C lock and strike L 7 7 16 3 23 32 Reinforce for strike attachment asrequired LHRshown RHRopposite 5 32 radius on 4 corners Aluminum frame 16 drill...

Reviews: