background image

Page 2 of 4

Figure 5

12 VDC input

nonpolarized

Red

Red-White

Black

Black-White

Figure 4

24 VDC input

nonpolarized

Red

Black

Red-White

Black-White

12 VDC, 0.38 A

24 VDC, 0.19 A

SOLENOID POWER

REQUIREMENTS

t

u

p

t

u

o

 

C

D

V

 

2

1

t

u

p

n

C

A

V

 

2

1

t

u

p

t

u

o

 

C

D

V

 

4

2

t

u

p

n

C

A

V

 

4

2

White

White

Yellow for 12 V

Red for 24 V

Black

SO kit

For DC operation, 

Von Duprin PS 861 and

Locknetics 593 DC

 series power supplies

are recommended.

For AC operation,

 Von Duprin SO-12 or 24

AC/DC convertor kit (shown below)

is recommended.

12 VDC Strike Wiring

24 VDC Strike Wiring

5.

Check power source voltage (12 or 24 VAC or VDC).

6.

When using 12 VAC or 24 VAC power, install SO kit to convert AC power to DC (Figure 4).

7.

Wire strike solenoid for proper voltage (Figure 5). 

Caution: Do not connect 24 VDC to 12 VDC configured strike.

8.

Test strike: Apply solenoid power. Fail secure (FSE) lip unlocks. Fail safe (FS) lip locks.

9.

If cut-out for strike is too large along edge (Figure 6), cut neoprene filler and stick onto strike as shown (Figure 7).

Note: This could occur in some retrofit applications.

Neoprene filler

Cut to length and

stick on strike

Figure 6

Figure 7

Gap filled

Summary of Contents for 5100

Page 1: ...fail secure FSE strike cannot be moved when strike is not powered If necessary remove backbox cover Figure 2 and changestrikemode by repositioning actuator Figure 3 1 For lock preparation see lock instructions 2 Install correct faceplate onto strike Figure 1 Figure1 Wiring must stay in slot 4 7 8 StandardANSI RoundCorner 10 24 flat head nylocscrews When using the electric strike in fail secure mod...

Page 2: ...or 24 AC DC convertor kit shown below is recommended 12 VDC Strike Wiring 24 VDC Strike Wiring 5 Check power source voltage 12 or 24 VAC or VDC 6 When using 12 VAC or 24 VAC power install SO kit to convert AC power to DC Figure 4 7 Wire strike solenoid for proper voltage Figure 5 Caution Donotconnect24VDCto12VDCconfiguredstrike 8 Test strike Apply solenoid power Fail secure FSE lip unlocks Fail sa...

Page 3: ...f frame does not have built in mounting tabs install mounting tabs supplied with strike as shown below Figure 8 Attach mounting tabs to strike with two 12 24 screws and mark 4 mounting tab holes on frame as shown below A B Drill four mounting holes C Mount the two mounting tabs inside frame using 10 24 screws as shown below D Shim strike in or out as needed until faceplate is flush with frame Fram...

Page 4: ...Cut out LongFaceplateSuggestedCut out L C lock and strike 31 32 4 1 8 4 7 8 5 8 2 7 16 1 1 4 2 1 16 C strike L 1 1 2 1 11 16 5 32 radius on 4 corners Aluminum frame 1 11 16 3 3 8 3 32 1 1 16 1 31 32 7 15 16 23 32 3 31 32 1 7 16 5 32 radius on 4 corners C lock and strike L 7 7 16 3 23 32 Reinforce for strike attachment asrequired LHRshown RHRopposite 5 32 radius on 4 corners Aluminum frame 16 drill...