Felkoder
44
PID 48, Code 2.9.2 Atmospheric pressure
Reason:
Air pressure is outside permissible values.
Reaction:
A fault code is generated. The fault code
disappears when the pressure returns to normal.
Monitoring function for air pressure is activated.
Action:
• Turn the ignition off and on, and check if the fault
code remains.
SID 253, Code 2.10.1 Parameter fault
Reason:
No data or incorrect data (fault only occurs
during parameter setting or reset).
Reaction:
Engine can not be started.
Action:
• Check parameter settings.
• Turn the ignition off and on, and check if the fault
code remains.
SID 240, Code 2.10.1 Stack overflow
Reason:
Internal calculation fault.
Reaction:
The engine is emergency stopped and
can not be re-started until the fault is rectified.
Action:
• Turn the ignition off and on, and check if the fault
code remains.