© Rototilt Group AB
2018-03-16
EN
English
Detach the tool
Position the tool horizontally, resting on
firm ground or so that the tool cannot
slide out of the attachment when the
quick coupler locks are opened.
!
IMPORTANT
- If the tool can fall or change position in
connection with the procedure, there is a risk of damaging
the tool and/or quick coupler.
!
IMPORTANT
- It is only possible to open the lock when
the start menu is visible or from the troubleshooting menu.
Operating Rototilt® Quick coupler
Check that the display shows the start
menu. The icon for the quick coupler
locking function is shown above the
green function key.
First press the green function key and
release it.
The buzzer sounds.
Now move the quick coupler locking
function switch to the open position.
The switch is enabled for a period of 10
seconds.
The lock remains open as long as the
switch remains open, but pressurising
is only performed during the preset time
period, 3-12 seconds.
The selected time can be checked on the
display,
Menu settings
.
The switch must be switched on and then
off again to repressurise the hydraulic
cylinder.
See the
Instructions for Use
for the quick
coupler
.
2200397_ _6909