Specifications
Electrical system
115
Fault messages in the digital display of the “PUMA” instrument panel
Fault messages without warning signal
The digital display shows a fault message in form of a fault code.
Fault message with warning signal
If a technical fault or defect occurs a fault message in form of a fault code is displayed by the digital display and
4 audible warning signals will be emitted.
The following fault messages in connection with a technical fault in the electric system can be rectified by the dri-
ver with minimum effort.
Fault
code
Warning
signal
Fault/
Incident
Cause
Remedy
SECURIT
no warning
signal
The starter cannot be
operated.
1. Engine running.
2. Left hand control
console is lowered.
Lift the left hand control con-
sole
ENTER
CODE
no warning
signal
Interruption of machine
by activated anti-theft
device.
Anti-theft device active. Enter the 4-digit code and
unlock the anti-theft device.
Fault
code
Warning
signal
Fault/
Incident
Cause
Remedy
FC1.01
4 audible war-
ning signals
Fault in main supply.
20A fuse defective
(main fuse)
FC1.02
4 audible war-
ning signals
Auxiliary supply for
unit.
20A fuse defective
(main fuse)
Check and replace fuse
FC1.03
4 audible war-
ning signals
Supply fault starter and
preheating relay.
5A fuse defective
WARNING!
If the fault could not be remedied by application of
the corrective measures you should consult your
Volvo CE dealer.
Summary of Contents for EC35
Page 1: ...OPERATOR S MANUAL Ref No VOE21B1002144 English Printed in Sweden CST ...
Page 38: ...Other controls 36 Operator s seat ...
Page 48: ...Operating instructions 46 Loading and unloading the machine ...
Page 82: ...Safety when servicing 80 Read before servicing ...
Page 138: ...Specifications 136 Service history ...
Page 140: ...Alphabetical index 138 Ref No VOE21B1002144 English Printed in Sweden CST Volvo Eskilstuna ...