24
TRACING FAULTS WITH INTERRUPTIONS IN OPERATION
The fault tracing scheme given below lists only the most usual reasons for faults that give
rise to interruptions in operation. With the help of the instructions given in this handbook,
the owner can generally remedy most of the reasons for the faults listed below. When in
doubt always contact the nearest Volvo Penta service shop.
Engine does not start
Engine stops
Engine does not reach correct
operating speed at full throttle
Engine runs unevenly or
vibrates abnormall
y
Engine becomes abnormally hot
Reason
See
X
Main switch not switched on; flat
battery, breakage in electric
cables or blown fuse.
pp 5, 12, 16,
17, 27
X
X
Empty fuel tank, closed fuel
cock, blocked fuel filter
pp 17, 18
X
X
X
Water, air or impurities in fuel
pp 17, 18, 19
X
X
X
X
Defective injector
pp 18, 26
X
X
Idling speed not properly
adjusted
p 25
X
Boat overloaded
X
Marine growth on boat bottom
X
Damaged propellor
X
Blockage in cooling water
intake, cooling jackets, defective
impeller, or thermostat
p 15