Engine, General
General inspection
Make a habit of visually checking the engine and
engine bay before starting, and after operations when
you have stopped the engine. This will help you to dis-
cover abnormalities quickly, or if something is about to
happen.
Look especially carefully for oil, fuel and coolant lea-
kages, loose bolts, worn or poorly-tensioned drive
belts, loose cable connections, damaged electrical
cables and hoses. This inspection only takes a few
minutes and can prevent serious malfunctions and
expensive repairs.
WARNING!
Accumulations of fuel, oil and grease on the engine or
in the engine room is a fire hazard and must be
removed immediately they are detected.
WARNING!
If an oil, fuel or coolant leak is detected, the cause must
be investigated and the fault rectified before the engine
is started.
Never direct the jet from a high-pressure washer at
seals, rubber hoses or electrical components. Never
use the high pressure setting for engine cleaning.
Crankcase Ventilation, Filter
Change
1 Undo the four cover bolts.
2 Move the cover forward/up so that the hose comes
loose from the air filter housing.
3 Remove the filter and insert a new one.
4 Slide the hose back into the air filter housing. Screw
the cover back in place.
IMPORTANT!
Scrap the old filter; it may not be cleaned.