201906-383-ENG
User manual - EOLE T1
P11
5. USE OF THE MACHINE
5.1. PREREQUISITES
• The electric connection has to be 230 V - 16 A - 50 or 60 Hz .
•
Be careful to only use paints which have not dried and which do not contain dry particles (otherwise,
filter the paint with a strainer).
•
Before use, verify the air filter foam (H). Replace it if it is used or missing by loosening the ring (D).
•
Choose the ideal needle kit depending on the paint which will be used. To change the nozzle,
loosen the ring (F)
So that the paint is at the ideal viscosity, use the viscosimeter delivered with the
turbine.
1 .
Dilute a part of the paint with the appropriate thinner.
2 .
Fill the viscosimeter to the top and allow the liquid to flow and monitor the time it takes
until the trickle of paint becomes discontinuous .
3 .
Check to see if the time corresponds to the indications in the table below:
- if the time is longer, increase the dilution
- if the time is less, add more paint
BUILDING PAINT
INDUSTRIAL PAINT
PRODUCTS
TIME
PRODUCTS
TIME
Oil paint
25 à 30 sec .
Hammered finish
30 à 50 sec .
Vinyl paint
30 à 35 sec .
Anti-rust
25 à 33 sec .
Acrylic paint
30 à 35 sec .
Lacquer, polyurethane
25 à 30 sec .
Pliolite
35 à 40 sec .
Lacquer, synthetic
22 à 27 sec .
Lacquer, brilliant, satin
25 à 27 sec .
Varnish, synthetic
20 à 22 sec .
Mat ceiling paint
25 à 30 sec .
Cellulosic
18 à 22 sec .
Anti-rust
25 à 33 sec .
Chromate and Wash-primer 18 à 22 sec .
Impression
20 à 25 sec .
Metallised
18 à 20 sec .