![Voltronic Power 1.5 KVA 12V User Manual Download Page 30](http://html1.mh-extra.com/html/voltronic-power/1-5-kva-12v/1-5-kva-12v_user-manual_1047779030.webp)
27
Table 3 Charge Mode Specifications
INVERTER MODEL
1.5K-12V
1.5K-24V / 3K-24V
Charging Algorithm
3-Step
Utility Charging Mode
AC Charging Current
2/10/20/30/40/50/60Amp (@V
I/P
=230Vac)
Bulk Charging
Voltage
Flooded Battery
14.6Vdc 29.2Vdc
AGM / Gel Battery
14.1Vdc 28.2Vdc
Floating Charging Voltage
13.5Vdc 27.0Vdc
Charging Curve
PWM Solar Charging Mode
Charging Current
50Amp
System DC Voltage
12Vdc 24Vdc
Operating Voltage Range
15~18Vdc 30~32Vdc
Max. PV Array Open Circuit Voltage
50Vdc 75Vdc
DC Voltage Accuracy
+/-0.3%
Joint Utility and Solar Charging
Max Charging Current
110Amp
Default Charging Current
60Amp
MPPT Solar Charging Mode
Charging Current
40Amp
PV Array MPPT Voltage Range
15Vdc ~ 80Vdc
30Vdc ~ 80Vdc
Max. PV Array Open Circuit Voltage
100Vdc
DC Voltage Accuracy
+/-0.3%
Joint Utility and Solar Charging
Max Charging Current
100Amp
Default Charging Current
60Amp
Table 4 General Specifications
INVERTER MODEL
1.5K-12V / 1.5K-24V / 3K-24V
Safety Certification
CE
Operating Temperature Range
-20°C to 55°C
Storage temperature
-30°C~ 60°C
Humidity
5% to 95% Relative Humidity (Non-condensing)
Dimension (DxWxH), mm
100 x 272 x 355
Net Weight, kg
7