Voltmaster Engine-Driven Generators
29
Operation: General maintenance
3.3.4
Storage
Store the generator in a warm, dry location.
If the generator is used infrequently, the engine could become
difficult to start. For gasoline-powered generators, a fuel additive
can help prevent this situation from occurring. See “Fuel additive”
on page 13.
Before putting the generator into storage for 6 months or longer,
follow these steps:
1.
Run the generator until it reaches normal operating temperature
(about 10 minutes) and then shut it down.
2.
For gasoline-powered generators, drain the fuel from the carburetor
bowl.
3.
While the engine is still warm, drain the oil from the engine base,
then fill with fresh oil.
4.
For gasoline-powered generators, remove the spark plug or plugs,
pour 1 ounce of engine oil into the cylinder or cylinders, crank the
engine slowly, and replace but do not tighten the spark plugs.
5.
Service the air cleaner.
6.
Plug the exhaust outlet to prevent moisture, bugs, and dirt from
entering.
7.
Clean off dirt and grease.
8.
Put a cover over the unit and store to avoid extreme heat or cold.