Voltmaster Engine-Driven Generators
25
Operation: Operating the generator
Figure 3.1 Fuel mixture adjustment screw
3.2.4
Starting the generator
Diesel recoil start
Some diesel generators feature electric-start engines with auxiliary
recoil starter. Before starting the engine on these models, if a
battery is not available, move the red or black lever near the fuel
pump to the up position. If a 12-volt battery is installed, the lever
must be in the down position at all times.
Air in fuel line
Air pockets in the fuel line will cause difficulty in starting and
operating the generator. Diesel generators are particularly
susceptible to air in the fuel line; Model XAF alternative-fuel
generators are not affected.
■
Before starting, pump the fuel lever 20 times or more.
■
Do not allow the generator to run out of fuel or to the bottom of the
fuel tank.
Fuel mixture adjustment
screw
Fuel mixture
nut