Volth S-36 Instruction Manual Download Page 8

     (7) 

Connect the test lead with the two ends of the diode, and then read the value 

         of forward voltage drop value.

     (8) 

When the test lead is under reverse connection or open-circuit status, the display 

          will display “OL”.   

    NOTE : a

When the resistance measured is above 1MΩ, it needs several seconds 

for the reading to be stable, it is normal when measuring high resistance. 

                 b

When measuring high resistance, insert the resistance pin directly into 

the V Ω and COM jack, so as to avoid interference 

                 c

When measuring resistance in a circuit make sure the power to the circuit is 

turned off and all capcitors are discharged,

    4.5 Measurement of capacitance  

                 Warning! When measurement of capacity, the measured capacitor should 

                                be completely discharged.

     (1) 

Turn the Rotary switch to “CAP” function. Plug red lead in “V/Ω” socket, and plug 

          black lead in “COM” socket. Warning:The range for capacitor can’t be set manually. 

          When the capacity value is large, the time for measurement may be a little longer. 

          a.         Do not take an external voltage or charged capacitor (especially a large 

              capacitor) connected to the test terminal  

          b. When a large capacitor is serious leakage or breakdown, the measurement 

              value may be instability

    4.6 Measurement of frequency / DUTY Ratio

     

(1) Turn the Rotary switch to “Hz” function.if you want to measure DUTY  Ratio, Press 

         SELECT key to switch

     (2) Plug red test lead in “V/Ω” terminal and plug black lead in “COM” terminal.

     (3) Connect the leads with measured circuit and then read the reading.

     (4) when the voltage exceeding 30V, please enter the Voltage  frequency measurement  

          mode by pressing the SELECT key in the “ACV” measurement function. 

    4.7 Measurement of temperature

 

          Turn the Rotary switch to the function of temperature, then plug the cold end (plug 

          end) of temperature sensor to the V/Ω and COM socket(black end for COM socket 

          and red end for V/Ω socket). Place the working end (temperature end) of the 

          sensor on or in the measured object. Then read the temperature value (in°C) on the 

           

°C display. If you need to measure that “°F”,  presses the SELECT key to switch.

                        Caution :

  When the cold terminal of the sensor isn’t inserted into the 

           meter, the meter might display approximate environmental temperature.

           K WRNM- 010 bare contact thermojunction has a limiting temperature of 250°C 

           (300°C for short time).

    

4.8 NON CONTACT VOLTAGE TESTING

          Turn the Rotary switch to the “     ” function, then the LCD display NCV and ~ symble, 

          plug red test lead in the “V/Ω” terminal and black lead without being used,place the 

          red test lead near the electric line, switch,or socket,the phase metal terminal need 

          not to be connected,when the detected voltage is above AC RMS 110V,a reverse C 

          will be displayed on the LCD,the higer the testing voltage is ,the more reverse C will 

          be display,with buzzer alarm sounds more intensive.  

                        Caution :

  1.even if there is no indication, voltage may still exist. Do not 

           judge the wire whether threre is voltage absolutely throught the non contact voltage 

           testing,the testing may be effected by many factors such as the socket design,the 

           insulation thickness and types etc. 2.Interference source of external environment,

           such as flash,motor etc,may false triggle the non contect voltage testing.

V. Maintenance of meter

                 Warning! Switch off the power, remove the test lead and any of input 

                                signals to prevent electric shock before opening the cover of 

                                meter or the cover of battery.  

    5.1 When the meter displays the symbol of “           ”, the battery should be changed. 

          Open the battery cover, and then change the used battery with new battery to 

          ensure the normal operation of the meter.

    5.2  Keep the meter and the pens clean, dry and non-destructive. Clean cloth or 

          detergent may be used for cleaning the cover of the meter. No grinding agent or 

          organic solvent can be used for the same cleaning purpose.

    5.3 The meter should be protected against damage, vibration and impact. 

          It shouldn’t be placed where high temperature or intense magnetic field exists.

    5.4 Calibrating of the meter is done on a yearly basis.

VI. Accessories

    6.1 Test lead: 1 set

    6.2 Users manual: 1 piece

    6.3 Temperature sensors: 1 set

    6.4 Cloth bag: 1piece

Summary of Contents for S-36

Page 1: ...S 36 1000A AC Auto range Clamp Meters 1000A AC Auto range Clamp Meters S 36 S 36 S 36 Make industrial job easy with In rush current...

Page 2: ...fety standard The meter in structure complies with the safety requirements of ICE61010 1 Read the instruction carefully as follows before you use the meter 1 When measuring voltage AC or DC voltage sh...

Page 3: ...ncluding battery s weight 3 2 Technical speci cations Accuracy reading digit calibration term is one year Ambient temperature 23 C 5 C Ambient humidity 70 RH 3 2 1 DCV 3 2 2 ACV Frequency 10Hz 1kHz Wa...

Page 4: ...function switch to the ACV measured function and press SELECT key to enter voltage frequency measured function in order to avoid demage the instrument 3 2 7 Duty Overload protection effective value 25...

Page 5: ...may change the measuring range by pressing this button press this key to cycle from small to large range of each function 6 INRUSH measuring Inrush voltage current key in AC measuring function press...

Page 6: ...clamp and hold wire put the wire in the clamp center read the reading directly NOTE 1 INRUSH measuring can only be manually setting range when the current value being measuring is unknow turn the rota...

Page 7: ...to measure DUTY Ratio Press SELECT key to switch 2 Plug red test lead in V terminal and plug black lead in COM terminal 3 Connect the leads with measured circuit and then read the reading 4 when the v...

Page 8: ...g the cover of meter or the cover of battery 5 1 When the meter displays the symbol of the battery should be changed Open the battery cover and then change the used battery with new battery to ensure...

Reviews: