Volth S-36 Instruction Manual Download Page 4

              

3.2.4  Resistance Ω

 

Overload protection: effective value 220V 

              

3.2.5 Capacitance 

Overload protection: effective value 250V 

warning

There is  about 20pF dead zone in the 10nF,capacitance below 20pF can not 

                 be measured

              

3.2.6 Frequency 

Overload protection: effective value 250V . Input sensitivity RMS: effective value 1V . 

NOTE: If the voltage of the frequency being measured is above 30V,set the rotary function 

switch to the ACV measured function and press “SELECT”key to enter voltage frequency 

measured function,in order to avoid demage the instrument. 

              

3.2.7 Duty

Overload protection: effective value 250V . input sensitivity RMS

1V 

Range  

 

           Accuracy 

 

Resolution 

400Ω  

 

           ±(1%+3d) 

 

0.1Ω 

4kΩ  

 

 

 

 

40kΩ  

 

 

 

 

10Ω

400kΩ  

 

 

 

 

100Ω

4MΩ 

 

 

 

 

1kΩ 

40MΩ  

 

           ±(1.5%+3d) 

 

10kΩ

Range  

 

           Accuracy 

 

Resolution 

10nF  

 

           ±

2.5%+5d

  

0.001nF 

100nF  

 

           ±

2.5%+5d

  

0.01nF 

1uF 

 

 

    0.1nF

10uF 

 

    1nF 

100uF 

 

    10nF

1000uF 

 

    100nF 

10mF 

 

           ±

3.0%+5d

  

1uF 

Range  

 

           Accuracy 

 

Resolution 

1%~99% 

 

           ±

0.5%+3d

  

0.1%

Range  

 

           Accuracy 

 

Resolution 

100Hz  

 

           ±

0.3%+3d

  

 

0.01Hz 

1kHz 

 

    0.1Hz 

10kHz 

 

    1Hz

100kHz 

 

    10Hz

1MHz 

 

    100Hz

10MHz 

 

    1kHz

40MHz 

    10kHz 

Summary of Contents for S-36

Page 1: ...S 36 1000A AC Auto range Clamp Meters 1000A AC Auto range Clamp Meters S 36 S 36 S 36 Make industrial job easy with In rush current...

Page 2: ...fety standard The meter in structure complies with the safety requirements of ICE61010 1 Read the instruction carefully as follows before you use the meter 1 When measuring voltage AC or DC voltage sh...

Page 3: ...ncluding battery s weight 3 2 Technical speci cations Accuracy reading digit calibration term is one year Ambient temperature 23 C 5 C Ambient humidity 70 RH 3 2 1 DCV 3 2 2 ACV Frequency 10Hz 1kHz Wa...

Page 4: ...function switch to the ACV measured function and press SELECT key to enter voltage frequency measured function in order to avoid demage the instrument 3 2 7 Duty Overload protection effective value 25...

Page 5: ...may change the measuring range by pressing this button press this key to cycle from small to large range of each function 6 INRUSH measuring Inrush voltage current key in AC measuring function press...

Page 6: ...clamp and hold wire put the wire in the clamp center read the reading directly NOTE 1 INRUSH measuring can only be manually setting range when the current value being measuring is unknow turn the rota...

Page 7: ...to measure DUTY Ratio Press SELECT key to switch 2 Plug red test lead in V terminal and plug black lead in COM terminal 3 Connect the leads with measured circuit and then read the reading 4 when the v...

Page 8: ...g the cover of meter or the cover of battery 5 1 When the meter displays the symbol of the battery should be changed Open the battery cover and then change the used battery with new battery to ensure...

Reviews: