Volth S-36 Instruction Manual Download Page 3

           3.1.5  Auto negative polarity indication: Displaying “-”.  

           3.1.6 Lack of battery power: Displaying “              ”.  

           3.1.7 Auto power OFF  After turning on the instrument and without turning the 

                    function switch or pressing any button, the instrument will automatically enter 

                    into sleep mode after 10 minutes,to save battery power.when it is in the sleep 

                    mode you can press the SELECT key to wake up the instrument. If you 

                    don't need the automatic sleep mode, you should hold down the DH key to 

                    turn on the instrument, and then  the symbol "        " will not be display on 

                    the LCD. 

           3.1.8 Work environment: 0°C-40°C, 75%RH. 

           3.1.9 Storage environment : -10°C-60°C, 85%RH. 3.1.10  battery : 3V (AA1.5V×2) 

           3.1.11 External dimensions: 249

 (

L

)

×89

 (

W

)

×38

 (

H

)

mm 

              

3.1.12 Weight: About 360g (including battery’s weight)

     3.2 Technical specifications 

           Accuracy

±(% r digit); calibration term is one year. Ambient temperature

           : 23°C±5°C;   Ambient humidity: ≤70%RH 

              

3.2.1 DCV 

              

3.2.2 ACV

Frequency

10Hz~1kHz (Warning

Frequency for square wave accuracy is specified 

from 10Hz to 400Hz)

display

TRUE RMS(sinusoidal waveform RMS calibration)

Overload protection:250V at mV range, DC1000V or peak value AC1000V at V range

              

3.2.3 ACA

AC Conversion Type

TRUE RMS responding, calibrated readings consistent with 

sinusoidal waveform RMS. Frequency Range:50~60Hz

Range  

                    Accuracy  

                Resolution  

             Input impendance

400mV  

                    ±(0.8%+2d) 

                0.1mV  

              About 10MΩ 

4V 

 

 

                0.001V  

              About 10MΩ 

40V  

 

 

                0.01V  

              About 10MΩ 

400V   

  

  

                0.1V  

              About 10MΩ 

1000V  

                    ±(1%+2d) 

                1V     

              About 10MΩ 

Range  

                    Accuracy  

                Resolution  

             Input impendance

400mV  

                    ±(1.0%+5d) 

                0.1mV  

              About 10MΩ 

4V 

 

 

                0.001V  

              About 10MΩ 

40V  

 

 

                0.01V  

              About 10MΩ 

400V   

  

  

                0.1V  

              About 10MΩ 

700V  

                    ±(1.5%+5d) 

                1V     

              About 10MΩ 

Range  

 

           Accuracy 

 

Resolution 

4A 

 

           ±(2%+5d) 

 

1mA 

40A 

    10mA 

400A 

    100mA

10

00A 

    1A

Summary of Contents for S-36

Page 1: ...S 36 1000A AC Auto range Clamp Meters 1000A AC Auto range Clamp Meters S 36 S 36 S 36 Make industrial job easy with In rush current...

Page 2: ...fety standard The meter in structure complies with the safety requirements of ICE61010 1 Read the instruction carefully as follows before you use the meter 1 When measuring voltage AC or DC voltage sh...

Page 3: ...ncluding battery s weight 3 2 Technical speci cations Accuracy reading digit calibration term is one year Ambient temperature 23 C 5 C Ambient humidity 70 RH 3 2 1 DCV 3 2 2 ACV Frequency 10Hz 1kHz Wa...

Page 4: ...function switch to the ACV measured function and press SELECT key to enter voltage frequency measured function in order to avoid demage the instrument 3 2 7 Duty Overload protection effective value 25...

Page 5: ...may change the measuring range by pressing this button press this key to cycle from small to large range of each function 6 INRUSH measuring Inrush voltage current key in AC measuring function press...

Page 6: ...clamp and hold wire put the wire in the clamp center read the reading directly NOTE 1 INRUSH measuring can only be manually setting range when the current value being measuring is unknow turn the rota...

Page 7: ...to measure DUTY Ratio Press SELECT key to switch 2 Plug red test lead in V terminal and plug black lead in COM terminal 3 Connect the leads with measured circuit and then read the reading 4 when the v...

Page 8: ...g the cover of meter or the cover of battery 5 1 When the meter displays the symbol of the battery should be changed Open the battery cover and then change the used battery with new battery to ensure...

Reviews: